agentsclimarketplace

The catalog

608,119 rows, by stacks then stars

  • Input output kernel regression for metabolite matching

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/input-output-kernel-regression-for-metabolite-matching Skill

    16★ repo

    Use when apply IOKR when you have BGCs with structural predictions based on MIBiG homology (cumulative BLAST score ≥10,000) and you wish to rank hypothetical BGC–spectrum links using metabolite structure information rather than genomic or strain-based features alone.

  • Installation troubleshooting

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/installation-troubleshooting Skill

    16★ repo

    Use when when setting up matchms for the first time in a new environment, after upgrading Python or conda, when switching between package managers (pip vs conda), or when distributing matchms to end users to confirm functionality across supported installation channels.

  • Installation validation and diagnostics

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/installation-validation-and-diagnostics Skill

    16★ repo

    Use when after installing a package via conda or pip from a distribution channel (e.g., Bioconda, PyPI), run this skill to confirm the installation succeeded and that critical submodules are importable before proceeding to use the package in analysis workflows.

  • Installation validation reporting

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/installation-validation-reporting Skill

    16★ repo

    Use when when deploying a new Python package in a reproducible analysis environment or continuous integration pipeline, and you need to confirm that all required core modules (e.g., pyteomics.mass, pyteomics.pepxml, pyteomics.mzid, pyteomics.tandem, pyteomics.

  • Instrument metadata classification

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/instrument-metadata-classification Skill

    16★ repo

    Use when when preprocessing a heterogeneous spectral library (e.g., GNPS public library) that contains spectra from multiple instrument types, and you need to partition data by a single instrument class to train or evaluate a formula-prediction model.

  • Instrument platform compatibility mapping

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/instrument-platform-compatibility-mapping Skill

    16★ repo

    Use when when adopting a mass spectrometry data processing tool (e.g., LipidMatch) and needing to verify whether your specific instrument platform (vendor + model) and acquisition mode combination (targeted, ddMS2-topN, AIF, direct infusion, imaging) have been formally validated.

  • Instrumental drift detection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/instrumental-drift-detection Skill

    16★ repo

    Use when you have a time-series of repeated QCpool (pooled quality control) injections measured at regular intervals during one or more LC-MS/MS sequences, exported from Sciex Multiquant software (v3.0.

  • Instrumental parameter validation mass spectrometry

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/instrumental-parameter-validation-mass-spectrometry Skill

    16★ repo

    Use when when you have obtained a raw Orbitrap mass spectrometry file and need to verify that the instrument was configured as claimed in the methods section or dataset documentation—especially before investing in peptide fragmentation analysis, spectrum library matching, or quantitative proteomics.

  • Intensity dependent missing value simulation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/intensity-dependent-missing-value-simulation Skill

    16★ repo

    Use when augmenting mass spectrometry ion images in ISO mode (isotope ions from the same molecule) and you need to simulate intensity-dependent data loss that reflects real detector behavior where lower-intensity pixels are more likely to be missed or undetected.

  • Intensity drift artifact detection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/intensity-drift-artifact-detection Skill

    16★ repo

    Use when processing raw MS intensity tables from long measurement sequences where you observe systematic, time-dependent changes in signal magnitude (e.g., progressive increase or decrease in peak intensity across a run).

  • Intensity normalization and scaling

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/intensity-normalization-and-scaling Skill

    16★ repo

    Use when when working with raw or filtered MsmsSpectrum objects where peak intensities span a wide dynamic range and need to be normalized for downstream spectrum comparison, database matching, or publication-quality visualization.

  • Intensity threshold noise filtering

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/intensity-threshold-noise-filtering Skill

    16★ repo

    Use when you have loaded a raw or partially processed MsmsSpectrum object and need to reduce spectral noise before annotation, matching, or visualization. Use it especially when spectra contain many weak peaks (e.

  • Intensity to concentration conversion

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/intensity-to-concentration-conversion Skill

    16★ repo

    Use when you have raw MS intensity data paired with measurements from known concentration standards, and you need to produce absolute quantified concentration values rather than relative intensity measurements.

  • Inter sample variance calculation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/inter-sample-variance-calculation Skill

    16★ repo

    Use when after applying batch correction (e.g., via pycombat) to a multi-batch feature table, to validate whether the correction has reduced systematic intensity differences between batches.

  • Inter scan interval validation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/inter-scan-interval-validation Skill

    16★ repo

    Use when after acquiring a PRM experiment on a Thermo Fisher Orbitrap instrument when you need to verify that the mass spectrometer's data acquisition controller executed the scheduled method with correct temporal spacing.

  • Interactive application accessibility testing

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/interactive-application-accessibility-testing Skill

    16★ repo

    Use when after instantiating a specXplore dashboard session layer with a loaded session data object from disk, before conducting visual exploration of LC-MS/MS spectral data.

  • Interactive html figure generation plotly

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/interactive-html-figure-generation-plotly Skill

    16★ repo

    Use when your mass spectrometry DataFrame contains m/z, retention time (or mobility), and intensity columns, and you need to generate an interactive HTML figure for exploration, web-based presentation, or interactive supplementary material.

  • Interactive network visualization rendering

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/interactive-network-visualization-rendering Skill

    16★ repo

    Use when after structural clustering (isotopologue grouping, adduct detection, cross-assay linking) and correlation clustering of LC-MS features, when you need to inspect and communicate the topology of structural relationships—particularly when the number of features or link types is too dense for.

  • Internal standard area mis injection flagging

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/internal-standard-area-mis-injection-flagging Skill

    16★ repo

    Use when after building a SummarizedExperiment object containing LC-MS peak areas and internal standard assignments, when you need to identify study samples with anomalous Internal Standard signal (indicating syringe failure, capillary clogging, or injection system malfunction) before applying.

  • Internal standard selection optimization

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/internal-standard-selection-optimization Skill

    16★ repo

    Use when after batch correction of metabolomics QC samples using pooled study quality control (SQC) samples, when you have multiple candidate internal standards and need to determine which one stabilizes the compound/internal standard ratio for each compound.

  • Internal standardization lipid mapping

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/internal-standardization-lipid-mapping Skill

    16★ repo

    Use when you have (LC-)IM-MS lipidomics data from samples spiked with U13C-labeled yeast extract, measured CCS values for both labeled and unlabeled lipids, and need to quantify systematic CCS bias between your instrument and a reference library before applying bias correction.

  • Internal standardization with isotope labels

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/internal-standardization-with-isotope-labels Skill

    16★ repo

    Use when your IM-MS lipidomics samples have been spiked with fully labeled isotopic internal standards (e.

  • Interoperability testing

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/interoperability-testing Skill

    16★ repo

    Use when when a new file format specification exists as a living document (e.

  • Interquartile range filtering for outlier rejection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/interquartile-range-filtering-for-outlier-rejection Skill

    16★ repo

    Use when when you have ensemble predictions (e.g., from Monte-Carlo Dropout inference with N ≥ 10 forward passes per input) and need to distinguish high-confidence from uncertain predictions before downstream analysis.

  • Iokr fingerprint space ranking

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/iokr-fingerprint-space-ranking Skill

    16★ repo

    Use when when you have paired MS2 spectra and BGCs with structural candidates (e.g., from MIBiG homology), and you want to rank which BGC likely produces which spectrum using a compound-class-agnostic method.

  • Ion count percentage calculation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-count-percentage-calculation Skill

    16★ repo

    Use when after applying one or more mpactr filters (mispicked, group, cv, insource) to an mpactr object and generating a qc_summary() data.

  • Ion image augmentation design

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-image-augmentation-design Skill

    16★ repo

    Use when when preparing ion image data from mass spectrometry imaging for contrastive self-supervised representation learning, and you need to generate augmented image pairs that reflect either co-localization relationships between different molecular ions (COL mode) or isotopic relationships.

  • Ion image embedding optimization

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-image-embedding-optimization Skill

    16★ repo

    Use when you have 512-dimensional representation vectors output from ResNet18 encoders processing paired augmented ion images, and you need to prevent trivial solutions (representation collapse) during contrastive learning—specifically when optimizing for maximized similarity between augmentations.

  • Ion mobility arrival time conversion

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mobility-arrival-time-conversion Skill

    16★ repo

    Use when you have a feature table containing raw ion mobility arrival time measurements paired with experimentally assigned biomolecular class labels (e.g., lipid, protein, carbohydrate), and you need to compute CCS values for downstream structural or comparative analysis.

  • Ion mobility feature classification

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mobility-feature-classification Skill

    16★ repo

    Use when you have raw or processed TWIM-MS data (arrival time and m/z pairs) from multiple lipid, protein, or metabolite classes and need to classify features by biomolecular type before—or instead of—performing feature identification.

  • Ion mobility mass spectrometry data processing

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mobility-mass-spectrometry-data-processing Skill

    16★ repo

    Use when you have (LC-)IM-MS lipidomics data from samples spiked with U13C labeled internal standards (e.g., fully labeled yeast extract) and need to quantify and correct systematic CCS bias before downstream lipid identification or quantification.

  • Ion mobility mobilogram visualization

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mobility-mobilogram-visualization Skill

    16★ repo

    Use when when you have mass spectrometry data with ion mobility (drift time or 1/K₀) measurements as a continuous dimension and want to visualize intensity distributions across the ion mobility axis.

  • Ion mobility reference matching

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mobility-reference-matching Skill

    16★ repo

    Use when you have raw arrival-time data from TWIM-MS and need to convert it to collision cross section (CCS) values for multi-omic analysis.

  • Ion mode specific ccs model generation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-mode-specific-ccs-model-generation Skill

    16★ repo

    Use when you have tunemix reference data acquired in both positive and negative ion modes and need to establish independent CCS calibration curves for each mode. The skill is required when downstream CCS assignments must achieve R² ≥ 0.

  • Ion type assignment verification

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ion-type-assignment-verification Skill

    16★ repo

    Use when after calling MsmsSpectrum.annotate_proforma() to assign fragment ions to a mass spectrum, verify that each annotated peak has the correct ion_type ('b' or 'y'), charge state, and m/z deviation from the theoretical mass computed for that peptidoform.

  • Ionisation method hardware correspondence

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ionisation-method-hardware-correspondence Skill

    16★ repo

    Use when when evaluating whether a mass spectrometry analysis platform (such as mzmine) has comprehensive module support across multiple ionisation and separation techniques (LC, GC, IMS, MALDI MS imaging), or when planning a multi-technique MS study and needing to confirm that all intended.

  • Ionization mode annotation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ionization-mode-annotation Skill

    16★ repo

    Use when when converting MS/MS spectra from .msp format library files (e.g., MassBank) into a custom fragment library for metabolite annotation, and the source spectra are tagged with ionization mode information (positive or negative).

  • Ionization mode inference from acquisition metadata

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ionization-mode-inference-from-acquisition-metadata Skill

    16★ repo

    Use when when beginning preprocessing of a new LC-MS dataset with mzML files or raw acquisitions and you need to determine which ionization mode was used before running feature detection (Asari) or empirical compound grouping (khipu).

  • Ionization mode peak retention comparison

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/ionization-mode-peak-retention-comparison Skill

    16★ repo

    Use when when you have loaded a raw mass spectrum (e.g. ESI_NEG_SRFA.

  • Irt peptide calibration and scoring

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/irt-peptide-calibration-and-scoring Skill

    16★ repo

    Use when when you need to assess whether retention times measured on a given LC-MS run follow the expected linear relationship defined by iRT peptide standards (e.g., Pierce or Biognosys iRT peptides).

  • Isotope adduct annotation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotope-adduct-annotation Skill

    16★ repo

    Use when after completing peak picking, sample alignment, and before final MS2 spectrum extraction, when you have identified individual ion peaks across samples and need to link isotopic variants (e.

  • Isotope pattern and adduct assignment

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotope-pattern-and-adduct-assignment Skill

    16★ repo

    Use when after feature detection has produced a TSV feature table (from Asari or equivalent) containing m/z, retention time, and intensity columns, and before MS1 or MS2 annotation.

  • Isotopic pattern mispicking detection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopic-pattern-mispicking-detection Skill

    16★ repo

    Use when you have a peak table from tandem MS preprocessing (e.g., MS-DIAL, Metaboscape) and suspect that isotopic patterns have been incorrectly split during feature detection.

  • Isotopic signature validation and filtering

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopic-signature-validation-and-filtering Skill

    16★ repo

    Use when after isotope detection has enumerated C13 isotopologue patterns across m/z, drift time, and retention time dimensions, and you need to reduce false positives by retaining only well-populated isotopic signature clusters before annotation or export.

  • Isotopologue adduct cluster assignment

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopologue-adduct-cluster-assignment Skill

    16★ repo

    Use when after sample alignment and peak picking have produced an aligned feature table with m/z and retention time coordinates.

  • Isotopologue adduct cross assay link encoding

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopologue-adduct-cross-assay-link-encoding Skill

    16★ repo

    Use when after structural cluster assignment and correlation clustering are complete, and you need to represent the full set of structural relationships (isotopologues, adducts, cross-assay links, and correlation co-membership) in a single unified graph for interactive visualization, network.

  • Isotopologue mass offset calculation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopologue-mass-offset-calculation Skill

    16★ repo

    Use when you have a peak-picked feature table (HDF5 format with m/z, drift_time, retention_time, intensity columns) and need to identify and label isotopic signatures within singly charged species.

  • Isotopologue signature detection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/isotopologue-signature-detection Skill

    16★ repo

    Use when you have preprocessed, statistically significant LC-MS features (from multiple assays or a single assay) and need to group features that represent the same metabolite in different isotopic labeling states.

  • Java application build verification

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/java-application-build-verification Skill

    16★ repo

    Use when when you need to confirm that a Java project's GitHub Actions workflow (e.g., 'dev_build_release.yml') has completed successfully and generated usable build artifacts;

  • Java build artifact validation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/java-build-artifact-validation Skill

    16★ repo

    Use when when you need to verify that a Java project's automated build pipeline (GitHub Actions workflow) executes without errors and generates distributable artifacts (e.g., .deb installers, portable binaries, or .jar files).

  • Java source code inspection

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/java-source-code-inspection Skill

    16★ repo

    Use when when you need to understand how a Java application routes input data to processing modules based on declared data types, conditionally branches on instrument or format types (e.

  • Json data serialization and parsing

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-data-serialization-and-parsing Skill

    16★ repo

    Use when you have discovered Mass2Motifs via LDA and need to (1) load a pre-computed motifset JSON file (e.g., motifset_optimized.

  • Json directive application

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-directive-application Skill

    16★ repo

    Use when when you have extracted intermediate JSON conforming to the Experiment Description Specification and need to restructure, filter, sort, or aggregate records (e.

  • Json document enrichment

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-document-enrichment Skill

    16★ repo

    Use when when your project JSON document contains public identifiers (genome IDs, biosample accessions, etc.) that lack human-readable or linked metadata, and you need to populate those fields programmatically before storage or publication to enable full-text search, validation, or cross-linking.

  • Json parsing motifset extraction

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-parsing-motifset-extraction Skill

    16★ repo

    Use when you have completed the MS2LDA LDA modeling phase and possess motifset.json or motifset_optimized.json files containing inferred Mass2Motifs.

  • Json payload construction for nmr spectra

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-payload-construction-for-nmr-spectra Skill

    16★ repo

    Use when when you have NMR peak assignments (1H and 13C chemical shift values) and need to submit them to the /api/smart3/search endpoint for automated structure classification. Use this skill before making API calls to ensure peak data conforms to the expected JSON schema.

  • Json response parsing

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-response-parsing Skill

    16★ repo

    Use when you receive a JSON response from a REST API endpoint (e.g., TensorFlow Serving /model/metadata) and need to extract and validate specific fields such as model input names, signatures, or outputs.

  • Json response validation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-response-validation Skill

    16★ repo

    Use when after sending HTTP requests to API endpoints (such as /classify or /model/metadata on an NP-Classifier server) to verify that the response is parseable JSON and contains the expected output fields and metadata before attempting to extract or process the data programmatically.

  • Json schema output verification

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-schema-output-verification Skill

    16★ repo

    Use when after extracting tabular data into intermediate JSON form or after applying matrix conversion directives (e.

  • Json schema validation

    HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/json-schema-validation Skill

    16★ repo

    Use when after extracting tabular data into intermediate JSON representation (via tagging), or after manual JSON editing, and before converting to a target format (e.g., mwTab for Metabolomics Workbench).