Internal standard area mis injection flagging

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v1/skills/internal-standard-area-mis-injection-flagging

Use when after building a SummarizedExperiment object containing LC-MS peak areas and internal standard assignments, when you need to identify study samples with anomalous Internal Standard signal (indicating syringe failure, capillary clogging, or injection system malfunction) before applying.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill internal-standard-area-mis-injection-flagging

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

6.4 KB, ~1.1k tokens by cl100k_base, as published. Nobody here has run it

internal-standard-area-mis-injection-flagging

Summary

Detect and flag mis-injected study samples in metabolomics LC-MS data by testing whether Internal Standard peak areas fall outside expected ranges, identifying technical failures that compromise quantitation reliability.

When to use

After building a SummarizedExperiment object containing LC-MS peak areas and internal standard assignments, when you need to identify study samples with anomalous Internal Standard signal (indicating syringe failure, capillary clogging, or injection system malfunction) before applying batch correction or concentration calculations.

When NOT to use

  • Input samples have no assigned internal standards or lack Internal Standard peak area measurements.
  • All study samples have uniform Internal Standard areas (no variance to detect outliers).
  • You are analyzing only QC or calibration-line samples; mis-injection testing is specific to Study Samples.

Inputs

  • SummarizedExperiment object with assay containing Internal Standard peak areas
  • colData with sample type annotations (Study Sample vs. QC vs. Calibration Line)
  • rowData mapping compounds to assigned internal standards

Outputs

  • SummarizedExperiment with colData$use column marked FALSE for flagged mis-injected samples
  • Metadata annotations in colData identifying detected outliers and mis-injection status

How to apply

Invoke doAnalysis with removeOutliers=TRUE on a SummarizedExperiment containing study samples with assigned internal standards. The function calculates the median Internal Standard area across all study samples in each batch, then tests each study sample's Internal Standard area against this batch median using statistical outlier detection (Rosner Test). Samples flagged as outliers (with extremely low or high Internal Standard areas) are marked with metadata annotations in the colData slot, indicating potential mis-injection. These flagged samples should be excluded from downstream analyses (via the 'use' column in colData) or investigated manually. The rationale is that internal standards are spiked at constant amounts; deviation signals instrumental failure rather than biological variation.

Related tools

  • mzQuality (Implements doAnalysis function for outlier detection and flagging of mis-injected study samples using Internal Standard areas) — https://github.com/hankemeierlab/mzQuality
  • SummarizedExperiment (Bioconductor object class used to store peak areas, sample metadata, and outlier flags in colData and rowData slots)
  • mzQualityDashboard (Interactive Shiny application providing visualization and manual curation of flagged mis-injected samples) — https://github.com/hankemeierlab/mzQualityDashboard

Examples

exp <- doAnalysis(exp = exp, removeOutliers = TRUE, useWithinBatch = TRUE); flagged_samples <- exp$use == FALSE; exp_filtered <- exp[, exp$use]

Evaluation signals

  • Flagged study samples (colData$use = FALSE) have Internal Standard areas > 2–3 standard deviations from batch median.
  • Rosner Test p-value for flagged samples is < 0.05, confirming statistical significance of the outlier.
  • Samples with extremely low Internal Standard areas (< 10% of batch median) correspond to known injection system failures or manual notes in the lab notebook.
  • After filtering flagged samples, batch-corrected assays (ratio_corrected) show reduced variance in QC sample ratios (RSDQC improvement).
  • Manual inspection of chromatograms or instrument logs confirms technical anomalies (e.g., syringe blockage, column pressure spike) on flagged injection dates.

Limitations

  • Mis-injection detection relies on Internal Standard area alone; if the internal standard itself is unstable or co-elutes with matrix, false positives may occur.
  • The method assumes all study samples receive the same injection volume and internal standard amount; variable internal standard addition will confound outlier detection.
  • In batches with very few study samples (n < 5), the batch median is unreliable and the Rosner Test may lack statistical power.
  • Outlier flagging is applied only to Study Samples; QC samples are tested separately using Compound/Internal Standard ratios, not raw Internal Standard areas.

Evidence

  • [intro] Study Samples are tested for mis-injections using their Internal Standard areas.: "Furthermore, Study Samples are tested for mis-injections using their Internal Standard areas."
  • [intro] The doAnalysis function with removeOutliers=TRUE flags QC and study sample outliers.: "Invoke doAnalysis with parameters removeOutliers=TRUE to flag QC sample outliers based on Compound/Internal Standard ratios"
  • [intro] Output includes metadata marking detected outliers and mis-injected samples.: "Generate output SummarizedExperiment containing the 'ratio_corrected' assay with batch-corrected compound/internal-standard ratios and metadata annotations marking detected outliers and mis-injected"
  • [other] Selection is based on Rosner Test for statistical outliers in QC samples.: "For samples, this is based on the outcome of the Rosner Test, which tests for statistical outliers in QC samples."
  • [other] The 'use' column in colData and rowData indicates reliability for reporting.: "mzQuality adds a column called use in both the rowData and colData slots of the SummarizedExperiment. These contain either a TRUE or FALSE value, indicating if the compound or sample is"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.