Product & growth
14,956 rows, by stacks then stars
865 of these skill files have been read, by 694 distinct authors, and what they tell an agent counted. What Product & growth authors agree on, and what they forbid
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-filtering Skill
16★ repoUse when working with GCIMS datasets where retention time spans a wide range (e.g., 0–1500 s) but your analytes of interest are confined to a narrower window (e.g., 0–1100 s).
Retention time index calibration
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-index-calibration Skill
16★ repoUse when you have acquired a bottom-up proteomics LC-MS/MS run (e.
Retention time indexed spectral aggregation
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-indexed-spectral-aggregation Skill
16★ repoUse when you have Thermo Fisher Scientific .raw files from an LC-MS experiment and need to extract spectral features (base-peak m/z, intensity, scan-level properties) indexed by retention time for downstream statistical analysis, method optimization, or diagnostic visualization.
Retention time intensity data extraction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-intensity-data-extraction Skill
16★ repoUse when you have xcms-processed LC-MS data with detected misaligned feature groups and need to recover the underlying raw retention time–intensity profiles for each feature and sample combination prior to realignment.
Retention time intensity extraction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-intensity-extraction Skill
16★ repoUse when when you have imported mass spectrometry data in .raw, .d, or mzXML format and need to generate a TIC plot to visualize overall sample ionization intensity as a function of retention time.
Retention time intensity tabulation
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-intensity-tabulation Skill
16★ repoUse when when you have a resolved mzML or mzXML spectrum file and need to visualize or analyze the temporal intensity profile of a specific analyte (defined by its m/z value).
Retention time mapping spline fitting
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mapping-spline-fitting Skill
16★ repoUse when after anchor feature pairs (m/z and retention time values) have been selected from two disparately-acquired LC-MS datasets, and you need to correct for systematic retention time differences between the datasets.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mass-alignment Skill
16★ repoUse when you have two independent LC-MS untargeted metabolomic feature datasets (each with retention time and m/z values) and need to identify which features in one dataset correspond to features in the other.
Retention time mass correspondence resolution
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mass-correspondence-resolution Skill
16★ repoUse when you have two LC-MS untargeted metabolomic feature tables (each containing m/z, retention time, and intensity columns) and need to establish which features in dataset A correspond to which features in dataset B, typically for comparative metabolomics, batch effect correction, or.
Retention time mass proximity matching
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mass-proximity-matching Skill
16★ repoUse when after sample alignment and grouping of isotopologues and adducts have been completed, when the aligned feature table contains NA or zero entries (missing intensities) for features that are detected in some samples but fall below the detection threshold in others.
Retention time mass tolerance calibration
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mass-tolerance-calibration Skill
16★ repoUse when you have multiple feature tables (CSV files) from different LC-MS analytical experiments, each containing mass, retention time, intensity, isotope, and adduct annotations, and you need to merge them into a single aligned feature matrix.
Retention time mz alignment matching
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-alignment-matching Skill
16★ repoUse when you have extracted feature tables (m/z, intensity, retention time) from multiple breath samples (mzML or mzXML files) via feature extraction, and need to identify which features represent the same volatile organic compound (VOC) across samples to enable cross-sample intensity comparisons.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-alignment Skill
16★ repoUse when processing raw LC/MS data (mzML or mzXML format) from multi-sample cohorts where retention time or intensity drift is suspected due to batch effects, instrument calibration drift, or variable run order.
Retention time mz coordinate mapping
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-coordinate-mapping Skill
16★ repoUse when when you have mass-spectrometry data in tabular form (Pandas DataFrame) with columns for m/z, retention time or ion mobility, and intensity, and you need to visualize the 2D distribution of peaks to assess peak separation, detect co-elution, or examine chromatographic and mass resolution.
Retention time mz feature extraction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-feature-extraction Skill
16★ repoUse when you have LC-HRMS profile-mode data (e.g., netCDF or mzML format) and need to convert detected or reference chromatographic peaks into fixed-size 2D arrays (rt × mz regions) to train or apply a convolutional neural network for peak classification and bounding-box prediction.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-indexing Skill
16★ repoUse when when you have parsed .mzML or Thermo .raw LC-MS data and need to support interactive or programmatic queries by retention time (RT) and mass-to-charge ratio (m/z) without re-scanning the entire file.
Retention time mz intensity mapping
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-mz-intensity-mapping Skill
16★ repoUse when you have processed LC-MS run data (feature table or peak detection output) containing internal standard identifications with retention times, m/z values, and intensity measurements across multiple samples, and you need to rapidly detect instrumental drift, retention time shifts, or.
Retention time normalization and scoring
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-normalization-and-scoring Skill
16★ repoUse when you have XCMS-aligned feature tables with retention time values and need to compute pairwise feature similarity.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-peak-flagging Skill
16★ repoUse when after applying peak detection algorithms to identify local maxima in feature signals across retention time or m/z dimensions, but before exporting or filtering the peak list for further analysis.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-peak-matching Skill
16★ repoUse when after drift correction and quality flagging, when you have a feature abundance matrix with associated metadata (Feature_ID, m/z, retention time) and need to identify which features likely represent the same underlying metabolite or adduct series before statistical analysis or metabolite.
Retention time prediction chromatography
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-chromatography Skill
16★ repoUse when you have a new chromatographic dataset with molecular structures (as InChI or SMILES) and experimentally measured retention times, and you want to predict retention times for unannotated metabolites or validate predictions on a held-out test set without retraining from scratch.
Retention time prediction from structures
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-from-structures Skill
16★ repoUse when you have molecular structures (SMILES or SDF format) for which you need to predict retention time in liquid chromatography, especially when your target dataset contains fewer than ~500 annotated examples.
Retention time prediction modeling
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-modeling Skill
16★ repoUse when you have a set of small-molecule compounds (e.g., from MS/MS library matching or database annotation) that require retention time validation or ranking to resolve ambiguous identifications.
Retention time prediction optimization
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-optimization Skill
16★ repoUse when when you have a retention-time dataset (e.g., SMRT or Eawag_XBridgeC18_364) in .xlsx format and need to train or adapt a graph neural network model to predict chromatographic retention times for new compounds.
Retention time prediction scoring
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-scoring Skill
16★ repoUse when you have a list of candidate metabolites for an unknown compound (from mass-to-structure search or library matching), experimental retention time(s) from one or more chromatographic methods, and access to a trained DNN RT predictor and meta-learned RT projection model.
Retention time prediction validation
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction-validation Skill
16★ repoUse when after training a GNN-RT model on preprocessed molecular graph data (from Train.py) or after applying transfer learning to an in-house dataset (from Transferlearning.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-prediction Skill
16★ repoUse when you have MS1-formatted mass spectrometry files from a liquid chromatography–mass spectrometry (LC-MS) experiment and need to predict the retention time of peptide ions without relying on spectral libraries, empirical models, or manual feature engineering.
Retention time projection across chromatographic methods
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-projection-across-chromatographic-methods Skill
16★ repoUse when when you have retention times measured on one chromatographic method and need to predict or map them to another method with minimal or no overlap in measured molecules.
Retention time range filtering
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-range-filtering Skill
16★ repoUse when you have raw IM-MS data (Agilent MassHunter .d or UIMF format) and need to exclude early or late chromatographic regions—e.g., to skip dead volume, exclude blank runs, focus on a known analyte window, or reduce file size for faster processing.
Retention time regression output specification
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-regression-output-specification Skill
16★ repoUse when after initializing and executing a forward pass through a dual-branch RT-Transformer model (combining fingerprint and molecular graph inputs) on a batch of molecular samples, to verify that the output tensor conforms to the expected shape, data type, and numeric range for retention time.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-scan-mapping Skill
16★ repoUse when when you have loaded an LC-MS spectrum file (mzML, mzXML, or equivalent) into the GNPS LCMS Visualization Dashboard and need to annotate extracted ion chromatograms with the precise retention time or scan ID positions where MS2 events occurred.
Retention time window clustering
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-window-clustering Skill
16★ repoUse when after filtering LC-MS features by statistical significance (e.g., p-value < 0.01) and you need to link individual m/z features into structural clusters representing the same metabolite in different ionization states or isotopic forms.
Retention time window extraction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-window-extraction Skill
16★ repoUse when you have loaded sqMass files containing pre-extracted transition group chromatograms and need to isolate chromatographic traces within a specific retention time interval—either defined by OpenSwath feature metadata (apex retention time ± margin) or by manual user selection.
Retention time window filtering
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-window-filtering Skill
16★ repoUse when you have mzML/mzXML chromatogram files from Thermo, Waters, or Bruker instruments and need to extract MS1 and MS2 scans matching both a target m/z value AND a known or suspected retention time range.
Retention time window tolerance checking
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-window-tolerance-checking Skill
16★ repoUse when you have acquired LC-MS data and need to verify run quality before proceeding to metabolite identification or quantification. Retention time checking is essential when: (1) you have established expected retention time ranges for known internal standards or reference compounds;
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/retention-time-windowing Skill
16★ repoUse when you have a complete TIC (total ion current) table indexed by retention time and need to visualize or analyze only a specific time interval—for example, when isolating a chromatographic peak region (9–10 min) before plotting or when a mass spectrometry run spans a time range wider than the.
Sample to reference retention time remapping
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/sample-to-reference-retention-time-remapping Skill
16★ repoUse when after mass tracks have been aligned across samples into a MassGrid structure and retention time calibration dictionaries (rt_cal_dict) have been computed for each sample during prior alignment steps.
Seed product relationship tracking
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/seed-product-relationship-tracking Skill
16★ repoUse when when applying biotransformation rules to seed metabolites to generate candidates, you need to record which rule produced each candidate and link it back to its parent seed structure. This is essential for downstream validation (e.
Separation efficiency calculation from retention times
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/separation-efficiency-calculation-from-retention-times Skill
16★ repoUse when you have extracted retention times from MS1 spectra for top signals in a single LC-MS/MS run and need to evaluate whether that gradient's separation performance is sufficient, or when you are building the objective function for an iterative gradient optimization loop where each candidate.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/shifted-dot-product-scoring Skill
16★ repoUse when matching query mass spectra to a spectral library in the presence of unknown post-translational modifications (PTMs) or non-enzymatic modifications.
Spectral data export and format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-data-export-and-format-conversion Skill
16★ repoUse when after running RAMClustR clustering on XCMS-processed metabolomics data, export spectral data when you need to share clustered spectra with external annotation software (MSFinder, Sirius), perform spectrum matching against reference databases, or prepare results for collaborative analysis.
Spectral data format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-data-format-conversion Skill
16★ repoUse when you have raw tandem mass spectrometry data in one or more of the vendor formats (MGF, mzML, or msp) and need to apply unsupervised topic modeling (LDA-based motif discovery) or comparative fragmentation analysis.
Spectral data table conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-data-table-conversion Skill
16★ repoUse when when you have mzPeak format spectrum files and need to work with spectrum metadata, intensity/m/z arrays, or precursor information in a tabular, columnar, or vectorized computing environment.
Spectral file format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-file-format-conversion Skill
16★ repoUse when when you have a GNPS molecular networking job archive (downloaded as a .zip or compressed archive) and need to prepare metabolomics spectra and molecular family data for NPLinker integration.
Spectral format conversion mzml to proprietary
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-format-conversion-mzml-to-proprietary Skill
16★ repoUse when after clustering features with RAMClustR and inferring molecular weights via do.findmain, when you need to perform structure elucidation or molecular formula prediction using MSFinder (for .mat format) or Sirius (for .ms format).
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-format-conversion Skill
16★ repoUse when when raw spectral data exists in one mass spectrometry file format but downstream analysis requires a different format; when integrating spectra from multiple sources or instruments that produce heterogeneous file formats;
Spectral library format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-library-format-conversion Skill
16★ repoUse when when you have mass spectral libraries from multiple sources (NIST, MoNA, RIKEN, GNPS) in disparate formats (MSP, MGF, MOL folder structures) or with misaligned metadata (e.
Spectral peak parent product pairing
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-peak-parent-product-pairing Skill
16★ repoUse when you have mass spectrometry imaging data with a histogram of pairwise mass differences that have already been matched to known adducts (via adductMatch), and you need to retrieve the actual mass peak pairs corresponding to a specific adduct of interest—particularly when you want to test.
Spectral peak retention signal noise discrimination
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-peak-retention-signal-noise-discrimination Skill
16★ repoUse when when you have replicate MS/MS spectra for the same feature (precursor m/z and retention time) and need to distinguish genuine fragment ions from noise.
Spectrum document conversion peak loss representation
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectrum-document-conversion-peak-loss-representation Skill
16★ repoUse when when preparing MS/MS spectral data for training word-embedding models (Word2Vec, Skip-gram, CBOW) that will learn relationships between fragment ions and neutral losses.
Structure file format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/structure-file-format-conversion Skill
16★ repoUse when you have raw structure input from diverse external databases (e.
Suspect list format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/suspect-list-format-conversion Skill
16★ repoUse when you have generated a set of transformation products (TPs) from one or more parent compounds using generateTPs (via BioTransformer, CTS, or PubChemLite library algorithms) and need to screen for these TPs in your LC-HRMS feature data.
Tabular data parsing and structure conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/tabular-data-parsing-and-structure-conversion Skill
16★ repoUse when you have a txt or tabular export file from a liquid chromatography–mass spectrometry (LC-MS) instrument (e.g., Sciex MultiQuant > v3.0.
Tensor operation element wise product
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/tensor-operation-element-wise-product Skill
16★ repoUse when you have two embedding tensors of identical shape (e.g., both 512-dimensional) and need to produce a fused representation that captures multiplicative interactions between modalities.
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/tensorflow-model-conversion Skill
16★ repoUse when you have downloaded pre-trained Keras models and need to prepare them for deployment in a TensorFlow Serving container. Use this skill when you must convert legacy or freshly downloaded Keras model files to HDF5 format for compatibility with TensorFlow 2.3.0 serving infrastructure.
Transformation product data extraction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/transformation-product-data-extraction Skill
16★ repoUse when after generating or obtaining a TP object (via generateTPs with library, in-silico, or BioTransformer algorithms) that contains SMILES, InChIKey, or formula information for transformation products, and you need to screen those TPs in LC-HRMS data or annotate them using MetFrag.
Transformation product parent linkage
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/transformation-product-parent-linkage Skill
16★ repoUse when after suspect screening has identified both parent features (from before-treatment or reference samples) and TP candidate features (from after-treatment or exposed samples) in the same analysis set, and you have MS/MS spectral data or formula annotations available.
Transformation product prediction
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/transformation-product-prediction Skill
16★ repoUse when after parent chemical suspects have been identified in a non-target screening workflow, use this skill when you need to screen for downstream products formed by chemical or biological transformation.
Vendor format to standard conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/vendor-format-to-standard-conversion Skill
16★ repoUse when when ingesting raw LC-MS/MS output from a mass spectrometry instrument and you need to prepare it for metabolite identification, fragmentation tree computation, or molecular formula annotation.
Visualization format conversion
HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/visualization-format-conversion Skill
16★ repoUse when you have generated exploratory data analysis plots (PCA, correlation heatmaps, missing-variable plots) in the pmartR Shiny interface and need to download them as static images for inclusion in reports, manuscripts, or presentations with specific width, height, and resolution requirements.