agentsclimarketplace

Performing scada hmi security assessment

Skill Mikaru0Mystic/sectinel/arsenal/Anthropic-Cybersecurity-Skills/skills/performing-scada-hmi-security-assessment

Open-source security arsenal for AI coding agents: 784 cybersecurity skills, scanner integrations, and a security MCP for Claude Code, Cursor, opencode, Gemini CLI, Cline, and any agentskills.io agent. Mapped to OWASP, MITRE ATT&CK, NIST CSF, D3FEND, ATLAS.

Install
npx -y skills add Mikaru0Mystic/sectinel --skill performing-scada-hmi-security-assessment

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 11 stars11 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its author says it does

Copied from the file, not written here

'Perform security assessments of SCADA Human-Machine Interface (HMI) systems to identify vulnerabilities in web-based HMIs, thin-client configurations, authentication mechanisms, and communication channels between HMI and PLCs, aligned with IEC 62443 and NIST SP 800-82 guidelines.

The file declares its own license as Apache-2.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

11.5 KB, ~2.6k tokens by cl100k_base, as published. Nobody here has run it

Performing SCADA HMI Security Assessment

When to Use

  • When assessing the security posture of HMI systems in SCADA/DCS environments
  • When evaluating web-based HMI interfaces for common web vulnerabilities
  • When auditing HMI authentication, authorization, and session management
  • When testing communication security between HMIs and PLCs/RTUs
  • When preparing for IEC 62443 or NERC CIP compliance assessments

Do not use for testing HMIs in active production without a maintenance window and rollback plan, for PLC-level protocol analysis (see performing-s7comm-protocol-security-analysis), or for general web application testing on non-OT systems.

Prerequisites

  • HMI system inventory with vendor, version, and network configuration details
  • Lab or test environment mirroring production HMI setup (preferred for active testing)
  • Authorization from plant operations for testing during maintenance windows
  • NIST SP 800-82 and IEC 62443 security requirements documentation
  • Network capture capability on HMI-to-PLC communication segment

Workflow

Step 1: Assess HMI Attack Surface

#!/usr/bin/env python3
"""SCADA HMI Security Assessment Tool.

Evaluates HMI security across authentication, communication,
configuration, and web interface categories aligned with
IEC 62443 and NIST SP 800-82 requirements.
"""

import json
import sys
from datetime import datetime
from typing import Dict, List

try:
    import requests
except ImportError:
    print("Install requests: pip install requests")
    sys.exit(1)


class HMISecurityAssessment:
    """Performs security assessment of SCADA HMI systems."""

    def __init__(self, hmi_info: dict):
        self.hmi_info = hmi_info
        self.findings = []
        self.checks_run = 0
        self.checks_passed = 0

    def check_authentication(self):
        """Assess HMI authentication mechanisms."""
        checks = [
            {
                "id": "AUTH-01",
                "name": "Password complexity enforcement",
                "iec62443_ref": "ISA-62443-3-3 SR 1.7",
                "description": "HMI must enforce minimum password complexity requirements",
                "test": "Verify minimum length >= 8, complexity rules, history >= 5",
            },
            {
                "id": "AUTH-02",
                "name": "Account lockout policy",
                "iec62443_ref": "ISA-62443-3-3 SR 1.11",
                "description": "HMI must lock accounts after failed login attempts",
                "test": "Verify lockout after 5 failed attempts, lockout duration >= 15 min",
            },
            {
                "id": "AUTH-03",
                "name": "Default credentials changed",
                "iec62443_ref": "ISA-62443-3-3 SR 1.5",
                "description": "All default vendor credentials must be changed",
                "test": "Attempt login with known vendor defaults (admin/admin, operator/operator)",
            },
            {
                "id": "AUTH-04",
                "name": "Role-based access control",
                "iec62443_ref": "ISA-62443-3-3 SR 2.1",
                "description": "HMI must separate operator, engineer, and admin roles",
                "test": "Verify operator role cannot access engineering functions",
            },
            {
                "id": "AUTH-05",
                "name": "Session timeout enforcement",
                "iec62443_ref": "ISA-62443-3-3 SR 1.12",
                "description": "HMI sessions must time out after inactivity",
                "test": "Verify session timeout <= 15 minutes for operator, <= 5 for admin",
            },
            {
                "id": "AUTH-06",
                "name": "Multi-factor authentication for remote access",
                "iec62443_ref": "ISA-62443-3-3 SR 1.13",
                "description": "Remote HMI access requires MFA",
                "test": "Verify MFA is enforced for all non-local HMI connections",
            },
        ]

        print(f"\n--- AUTHENTICATION ASSESSMENT ---")
        for check in checks:
            self.checks_run += 1
            print(f"  [{check['id']}] {check['name']}")
            print(f"    Ref: {check['iec62443_ref']}")
            print(f"    Test: {check['test']}")

    def check_communication_security(self):
        """Assess HMI-to-PLC communication security."""
        checks = [
            {
                "id": "COMM-01",
                "name": "Encrypted HMI-PLC communication",
                "description": "Traffic between HMI and PLCs should use encrypted protocols (OPC UA with TLS)",
                "test": "Capture HMI-PLC traffic and verify encryption (Wireshark TLS handshake)",
            },
            {
                "id": "COMM-02",
                "name": "HMI write command authentication",
                "description": "Write commands from HMI to PLC should be authenticated",
                "test": "Verify that write operations require operator confirmation/authentication",
            },
            {
                "id": "COMM-03",
                "name": "Web HMI uses HTTPS",
                "description": "Web-based HMI interfaces must use TLS 1.2+ with valid certificates",
                "test": "Check TLS version, cipher suites, certificate validity",
            },
            {
                "id": "COMM-04",
                "name": "No cleartext protocols in use",
                "description": "Telnet, FTP, HTTP must not be used for HMI access or management",
                "test": "Port scan HMI for cleartext protocol services",
            },
        ]

        print(f"\n--- COMMUNICATION SECURITY ASSESSMENT ---")
        for check in checks:
            self.checks_run += 1
            print(f"  [{check['id']}] {check['name']}")
            print(f"    Test: {check['test']}")

    def check_web_hmi_security(self):
        """Assess web-based HMI for common web vulnerabilities."""
        hmi_url = self.hmi_info.get("url", "")
        if not hmi_url:
            print(f"\n  [SKIP] No web HMI URL provided")
            return

        checks = [
            {
                "id": "WEB-01",
                "name": "Cross-Site Scripting (XSS)",
                "owasp": "A7:2017",
                "test": "Test input fields with XSS payloads in tag names, alarm messages",
            },
            {
                "id": "WEB-02",
                "name": "Cross-Site Request Forgery (CSRF)",
                "owasp": "A8:2013",
                "test": "Verify CSRF tokens on state-changing operations (setpoint changes)",
            },
            {
                "id": "WEB-03",
                "name": "Insecure Direct Object References",
                "owasp": "A4:2013",
                "test": "Manipulate URL parameters to access other users HMI views",
            },
            {
                "id": "WEB-04",
                "name": "Security Headers",
                "test": "Verify X-Frame-Options, CSP, X-Content-Type-Options headers",
            },
            {
                "id": "WEB-05",
                "name": "Privileged file system access (CVE-2025-0921)",
                "test": "Check Ignition SCADA for privileged file system vulnerability via project files",
            },
        ]

        print(f"\n--- WEB HMI SECURITY ASSESSMENT ---")
        print(f"  Target: {hmi_url}")
        for check in checks:
            self.checks_run += 1
            print(f"  [{check['id']}] {check['name']}")
            print(f"    Test: {check['test']}")

    def check_hardening(self):
        """Assess HMI operating system and application hardening."""
        checks = [
            {
                "id": "HARD-01",
                "name": "OS patch level",
                "test": "Verify HMI OS is patched within SLA (typically 90 days for OT)",
            },
            {
                "id": "HARD-02",
                "name": "Unnecessary services disabled",
                "test": "Verify no unnecessary network services running (RDP if not needed, SMB, etc)",
            },
            {
                "id": "HARD-03",
                "name": "USB port restrictions",
                "test": "Verify USB mass storage is blocked on HMI terminals",
            },
            {
                "id": "HARD-04",
                "name": "Application whitelisting",
                "test": "Verify only authorized HMI applications can execute",
            },
            {
                "id": "HARD-05",
                "name": "Audit logging enabled",
                "test": "Verify operator actions, login events, and setpoint changes are logged",
            },
        ]

        print(f"\n--- HMI HARDENING ASSESSMENT ---")
        for check in checks:
            self.checks_run += 1
            print(f"  [{check['id']}] {check['name']}")
            print(f"    Test: {check['test']}")

    def generate_report(self):
        """Generate assessment report."""
        self.check_authentication()
        self.check_communication_security()
        self.check_web_hmi_security()
        self.check_hardening()

        print(f"\n{'='*70}")
        print("SCADA HMI SECURITY ASSESSMENT SUMMARY")
        print(f"{'='*70}")
        print(f"Date: {datetime.now().isoformat()}")
        print(f"HMI: {self.hmi_info.get('name', 'Unknown')}")
        print(f"Vendor: {self.hmi_info.get('vendor', 'Unknown')}")
        print(f"Version: {self.hmi_info.get('version', 'Unknown')}")
        print(f"Total Checks: {self.checks_run}")
        print(f"Findings: {len(self.findings)}")


if __name__ == "__main__":
    assessment = HMISecurityAssessment(hmi_info={
        "name": "Plant-HMI-01",
        "vendor": "Siemens WinCC",
        "version": "7.5 SP2",
        "ip": "10.10.2.10",
        "url": "https://10.10.2.10:8080",
        "os": "Windows 10 LTSC 2021",
    })
    assessment.generate_report()

Key Concepts

TermDefinition
HMIHuman-Machine Interface providing operators visual representation and control of industrial processes
Web HMIBrowser-based HMI interface accessible via HTTP/HTTPS, subject to standard web vulnerabilities
SetpointTarget value for a process variable that operators can change through the HMI; unauthorized changes can cause process upset
Alarm SuppressionAttacker technique of disabling or hiding HMI alarms to mask malicious process manipulation
WinCCSiemens SCADA/HMI software widely deployed in manufacturing and process industries
CVE-2025-0921Ignition SCADA privileged file system vulnerability exploitable through malicious project uploads

Output Format

HMI SECURITY ASSESSMENT REPORT
=================================
Date: YYYY-MM-DD
HMI: [name] | Vendor: [vendor] | Version: [version]

FINDINGS BY CATEGORY:
  Authentication: [pass/fail count]
  Communication: [pass/fail count]
  Web Security: [pass/fail count]
  Hardening: [pass/fail count]

CRITICAL FINDINGS:
  1. [finding with remediation]

COMPLIANCE STATUS:
  IEC 62443 SL-T: [target level]
  IEC 62443 SL-A: [achieved level]

What ships with it: 3 files

20.3 KB alongside SKILL.md, 1 of them executable

references/

scripts/

Keep looking

Skills are one crate of 328,083. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.