Create sdi run
Skill matlab/simulink-agentic-toolkit/skills-catalog/simulink-simulation/create-sdi-run
The Simulink Agentic Toolkit gives your AI agent both the tools and the expertise to work effectively with Simulink and Model-Based Design.
npx -y skills add matlab/simulink-agentic-toolkit --skill create-sdi-runAssembled from the repository path, not quoted from the project. Check it against their README if it does not work.
One thing to look at
- no licenseNo license file was found in the repository. Code published without one is not open source by default, so using it at work is a question for whoever answers licensing questions where you are.
What its author says it does
Copied from the file, not written here
Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed `Simulink.sdi.createRun` or `sim(model)` produced. Covers the `'file'`, `'vars'`, and `'namevalue'` sources of `createRun`, the auto-populate behavior after `sim()`, and post-import verification. Not for comparing existing runs (use `Simulink.sdi.compareRuns`); not for streaming data live during a running simulation (use `Simulink.sdi.createRunOrAddToStreamedRun` — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use `testing-simulink-models`). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop.
The file declares its own license as MathWorks BSD-3-Clause. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.
SKILL.md
15.5 KB, as published. Nobody here has run it
Create SDI Run
Get data into the Simulation Data Inspector using the shortest path that works. Most agents reflexively read files into the workspace and rebuild signals by hand; this skill teaches the direct paths and when each applies.
When to Use
- User has a
.mat,.csv, or.xlsxfile of logged data and wants to view it in SDI. - User just ran
sim(model)and wants to see the logged signals. - User has
timeseries,timetable, orSimulink.SimulationData.Datasetvariables in the workspace and wants an SDI run. - User asks about
Simulink.sdi.createRun,Simulink.sdi.getAllRunIDs, orSimulink.sdi.getRun.
When NOT to Use
- Comparing two existing runs — that is a distinct workflow (
Simulink.sdi.compareRuns). - Streaming data live during a running simulation — this is a separate API (
Simulink.sdi.createRunOrAddToStreamedRun), not a mode ofcreateRun. Prompts like "stream data into SDI while my sim is running" belong to that API. Do not activate on those. - Files in MDF (
.mf4), ULG, ROS bag, CAN log, or HDF5 formats — see references/format-support.md for what SDI reads natively vs. what needs a different toolbox. - Customizing plot layout, cursors, or subplot arrangement beyond opening the SDI window.
- Authoring Gherkin
.featurefiles, Simulink Test cases,matlab.unittestclasses, or any pass/fail assertions or regression tests for a model or subsystem — usetesting-simulink-models(Gherkin-basedmodel_test, requires Simulink Test). Prompts like "write a Gherkin test for X", "verify abs(-5) equals 5", "create a regression test for this subsystem", or any request whose deliverable is a test artifact belong there. Do not activate this skill on such prompts even whentesting-simulink-modelsis unavailable — in that case, tell the user which skill is missing and stop.
Workflow
Answer these four questions in order. The first "yes" tells you what to do.
1. Is the data already in SDI?
After sim(model) with signal logging enabled, SDI auto-populates one run. Do not call createRun — that produces a duplicate.
before = Simulink.sdi.getAllRunIDs;
simOut = sim("myModel");
after = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
Simulink.sdi.view; % done — just open the window
end
If no new run appeared, logging is off. Enable it via the Simulink Agentic Toolkit model_edit tool with a configure op setting DataLogging on the target port, then re-simulate — or fall back to Step 3 with simOut. As a last resort, ask the user to right-click a signal → Log Selected Signals in the Simulink editor themselves; that step is for the user to perform, not the agent.
2. Is the data in a file?
Use the 'file' source. One call handles MAT, CSV, and Excel natively — no load, no readtable, no sheetnames loop.
runID = Simulink.sdi.createRun("bench_test","file","logs/bench_test.mat");
Excel with N sheets returns a 1×N int32 vector — one run ID per sheet. All returned runs inherit the base name; if the user needs sheet-named runs, rename each run in place with sheetnames() — do not delete and re-import per sheet:
runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx"); % [id1, id2, ...]
sheets = sheetnames("cases.xlsx");
for k = 1:numel(runIDs)
Simulink.sdi.getRun(runIDs(k)).Name = sheets(k);
end
Time-column header rule (CSV and Excel). SDI's built-in reader requires the time column to be named literally time (case-insensitive). Headers like time_s, t, Time (s), Timestamp cause SDI:sdi:ImportError. Try 'file' first and catch the error — do not pre-inspect the header row and guess, because SDI's matching rules can differ from your interpretation. On SDI:sdi:ImportError, fall back to the readmatrix + array2timetable + 'vars' pattern (Step 3 / CSV pattern below). Do not rewrite the source file.
Other createRun failures. createRun can also throw for reasons this skill does not enumerate — corrupted files, unsupported data types inside a MAT/Excel, malformed structs, permission errors, unregistered custom readers. When you catch an error identifier that is not SDI:sdi:ImportError, do not invent a fix or silently retry. Surface the full error identifier and message to the user, list the file or variables involved, and suggest they inspect the source (e.g., whos("-file",path) for a MAT, or sheetnames(path) plus a per-sheet read for an Excel). Ask before attempting an alternative import path.
3. Is the data in workspace variables?
Two sources, different purposes:
'vars'— pass variables whose names or.Nameproperties are already correct. This is the default.'namevalue'— pass explicit signal names when the variables have no.Namemetadata (e.g., bare arrays or unnamedtimeseries).
Timeseries whose .Name is already what you want:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", speedTS, torqueTS);
Timetable — signals inherit the column names:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", benchTT);
Bare arrays needing explicit names:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","namevalue", ...
{"velocity","load"}, {velocityData, loadData});
Gotcha (Gap E): if a timeseries passed to 'namevalue' has its own .Name set, .Name wins over the caller-supplied name. To force the name you want, either set ts.Name first and use 'vars', or clear it before 'namevalue'.
4. Verify the run
After every createRun or auto-populate:
ids = Simulink.sdi.getAllRunIDs;
run = Simulink.sdi.getRun(ids(end));
fprintf("Run %d: %s (%d signals)\n", ids(end), run.Name, run.SignalCount);
for k = 1:run.SignalCount
fprintf(" %s\n", run.getSignalByIndex(k).Name);
end
Simulink.sdi.view;
Verify against MATLAB via the MATLAB MCP server's evaluate_matlab_code tool. If SignalCount == 0, the import silently produced nothing — investigate the source, do not report success.
Key Functions
All available from R2023a with base Simulink; no additional toolbox required.
| Function | Purpose | Available From |
|---|---|---|
Simulink.sdi.createRun(name) | Empty run — used with Run.add for a per-signal build; rarely the right first choice. | R2011b |
Simulink.sdi.createRun(name,"file",path) | Import a .mat, .csv, or .xlsx file. Returns scalar int32 for MAT/CSV, 1×N int32 vector for N-sheet Excel. | R2011b |
Simulink.sdi.createRun(name,"vars",v1,v2,...) | Import workspace variables whose names/.Name are correct. | R2011b |
Simulink.sdi.createRun(name,"namevalue",names,values) | Import with explicit names. See Gap E caveat. | R2011b |
Simulink.sdi.view | Open the SDI window. Safe to call repeatedly; opens only if not visible. | R2011b |
Simulink.sdi.getAllRunIDs | Return int32 vector of every run's ID. Use before/after sim to detect auto-populate. | R2017a |
Simulink.sdi.getRun(runID) | Return the Simulink.sdi.Run object for a run ID. | R2011b |
Simulink.sdi.clear | Delete all SDI runs. Ask the user first — destructive. | R2011b |
Four createRun sources exist: empty, 'vars', 'namevalue', 'file'. When unsure, run help Simulink.sdi.createRun.
Patterns
Pattern: MAT file → SDI (one line)
runID = Simulink.sdi.createRun("sensor_log","file","data/sensor_log.mat");
Simulink.sdi.view;
The variables inside the MAT file may be timeseries, timetable, Simulink.SimulationData.Dataset, or legacy struct-with-time — SDI's reader picks them up automatically.
Pattern: CSV file → SDI (try 'file', catch, fall back)
Attempt the one-liner first. On SDI:sdi:ImportError, fall back to the timetable path — do not rewrite the file:
try
runID = Simulink.sdi.createRun("bench_run","file","logs/bench_run.csv");
catch ME
if strcmp(ME.identifier,"SDI:sdi:ImportError")
raw = readmatrix("logs/bench_run.csv");
headers = string(readcell("logs/bench_run.csv","Range","1:1"));
tt = array2timetable(raw(:,2:end), ...
"RowTimes", seconds(raw(:,1)), ...
"VariableNames", headers(2:end));
runID = Simulink.sdi.createRun("bench_run","vars", tt);
else
rethrow(ME);
end
end
Assumes the time column is column 1 and expressed in seconds — the common case for bench logs. If the time column sits elsewhere or uses different units, adjust the index or wrap it with the appropriate duration constructor (milliseconds, minutes, …) before passing to RowTimes.
Pattern: Excel with multiple sheets → one run per sheet
One createRun call per file. Every returned run initially inherits the base name you supplied — SDI does not auto-apply sheet names. Rename in place with sheetnames(); do not delete and re-import per sheet. The same time-column-header rule applies as for CSV — if a sheet's time column is not named time, createRun throws SDI:sdi:ImportError; wrap this call in the same try-then-fallback shown in the CSV pattern, using readmatrix(...,"Sheet",sheets(k)) and readcell(...,"Sheet",sheets(k),"Range","1:1") per sheet.
runIDs = Simulink.sdi.createRun("test_matrix","file","data/two_runs.xlsx");
% runIDs is a 1xN int32 vector — one ID per sheet, all named "test_matrix".
sheets = sheetnames("data/two_runs.xlsx");
for k = 1:numel(runIDs)
run = Simulink.sdi.getRun(runIDs(k));
run.Name = sheets(k); % rename in place to the sheet name
fprintf("Sheet run: %s (%d signals)\n", run.Name, run.SignalCount);
end
To restrict to specific sheets, use the sheets name-value — the returned vector is trimmed accordingly:
runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx", ...
sheets=["baseline","variant"]);
Pattern: Post-sim — just open SDI
before = Simulink.sdi.getAllRunIDs;
simOut = sim("controller_test");
after = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
Simulink.sdi.view; % logged signals already imported
else
% No auto-populate — logging is off. Enable it and re-simulate, or
% pass simOut through createRun as a fallback:
Simulink.sdi.createRun("run_from_simout","vars", simOut);
Simulink.sdi.view;
end
Pattern: Rename workspace signals
Set .Name before 'vars'. This avoids the 'namevalue' override trap.
data = load("data/speed_torque.mat");
speed = data.speed;
torque = data.torque;
speed.Name = "velocity";
torque.Name = "torqueNm";
runID = Simulink.sdi.createRun("baseline","vars", speed, torque);
Conventions
Always
- Check whether SDI already has the data before calling
createRun. UseSimulink.sdi.getAllRunIDsbefore and aftersim(model). If a new run appeared,simalready imported the logged signals — callSimulink.sdi.viewand stop. - Prefer the
'file'source for.mat,.csv,.xlsx. It handles the read and the signal-naming for you. Reserveload/readtable/sheetnamesfor the CSV time-column fallback and for genuinely workspace-first workflows. - Verify with
SignalCount. After every import, confirm at least one signal exists. Zero signals means the import failed silently. - Read
help Simulink.sdi.createRunif you are unsure which source applies. The four sources are the entire API surface for import.
Ask First
Simulink.sdi.clear— deletes every run. Confirm with the user before running.- Modifying the source file (e.g., renaming a CSV column to
time) — prefer the timetable fallback pattern instead of altering user data. - Attempting an alternative import path after a non-
SDI:sdi:ImportErrorfailure — surface the error to the user first, then ask which path they want.
Never
- Never invent function names.
Simulink.sdi.createRunFromFiledoes not exist. UseSimulink.sdi.createRun(name,"file",path). - Never rebuild a file-side workflow through
load/readtable/ manualtimeseriesconstruction /Run.addwhen the'file'source handles the same file natively. - Never assume
namevaluenames take precedence overtimeseries.Name—.Namewins. See Gap E in Common Mistakes. - Never claim success without inspecting
SignalCountand the signal names.
Common Mistakes
| Mistake | Why It's Wrong | Correct Approach |
|---|---|---|
Reading MAT/CSV/Excel yourself and calling createRun(...,"vars",...) | Duplicates the 'file' source's work; loses SDI's automatic signal-name handling; scales badly for multi-sheet Excel. | Simulink.sdi.createRun(name,"file",path). |
Deleting the multi-sheet import and re-calling createRun in a per-sheet loop because both runs share the base name | Discards the correct one-call 'file' import and violates the "single call handles sheet expansion" convention. All runs from one Excel file inherit the base name — they are not auto-renamed to sheet names. | Keep the one createRun(...,"file",xlsx) call and rename each run in place: Simulink.sdi.getRun(runIDs(k)).Name = sheets(k). |
Calling createRun(...,"namevalue",{"SimOut"},{simOut}) after sim(model) | With signal logging on, sim already imported the run. This adds a duplicate. | sim(model); Simulink.sdi.view; (verify with getAllRunIDs before/after). |
Using Simulink.sdi.createRunFromFile | Function does not exist. Hallucination. | Simulink.sdi.createRun(name,"file",path). |
Passing namevalue names when the timeseries has its own .Name | .Name overrides the caller-supplied name silently — Gap E. | Set ts.Name first, then use 'vars'. Or clear .Name before 'namevalue'. |
Pre-inspecting the header and skipping 'file' because you think the time column is misnamed | Your guess can differ from SDI's actual matching rules; skipping 'file' costs the automatic signal handling. | Try 'file' first, catch SDI:sdi:ImportError, then use the timetable fallback (Step 3 / CSV pattern). |
References
- references/format-support.md — which file formats SDI reads natively, which need a toolbox, which need conversion. Consult when the user has a file extension other than
.mat,.csv, or.xlsx. - references/createrun-signatures.md — the four
createRunsources side-by-side with return-value shapes and name-value options. Consult when picking a source or debugging return values.
Copyright 2026 The MathWorks, Inc.