Ft icr spectrum recalibration validation
Curated, evidence-grounded skill and software-tool collections for scientific AI agents, generated by the AgenticScienceBuilder
npx -y skills add HolobiomicsLab/asb-skill-collections --skill ft-icr-spectrum-recalibration-validationAssembled from the repository path, not quoted from the project. Check it against their README if it does not work.
One thing to look at
- 14 stars14 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.
What its author says it does
Copied from the file, not written here
Use when after applying mass calibration functions (LedFord, linear, or quadratic equations) to an FT-ICR transient or magnitude-mode dataset, before running SearchMolecularFormulas. Specifically, validate recalibration when: (1) comparing recalibrated spectra against reference calibration files (e.
The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.
SKILL.md
9.5 KB, ~1.7k tokens by cl100k_base, as published. Nobody here has run it
FT-ICR Spectrum Recalibration Validation
Summary
Validates the quality and accuracy of mass calibration in recalibrated FT-ICR mass spectra by assessing mass error distributions, resolving power, and peak assignment consistency across a 12 T field-strength instrument. This skill ensures that downstream molecular formula assignment relies on reliable m/z measurements within acceptable ppm error tolerances.
When to use
After applying mass calibration functions (LedFord, linear, or quadratic equations) to an FT-ICR transient or magnitude-mode dataset, before running SearchMolecularFormulas. Specifically, validate recalibration when: (1) comparing recalibrated spectra against reference calibration files (e.g., SRFA.ref), (2) transitioning between different calibration equations or calibration signal-to-noise thresholds, or (3) processing data from a new instrument configuration or magnetic field strength.
When NOT to use
- Input data are already centroided (peak-picked) or in profile mode without access to raw transient — recalibration requires raw time-domain or magnitude-mode data.
- No reference calibration file is available and the goal is absolute mass assignment rather than relative accuracy validation.
- Spectrum is from a low-resolution instrument (e.g., nominal mass accuracy) where ppm error tolerances and resolving power calculations are not applicable.
Inputs
- Bruker .d directory (recalibrated FT-ICR transient or magnitude-mode spectrum)
- Reference calibration file (.ref format, e.g., SRFA.ref)
- MSParameters object (noise_threshold_method, noise_threshold_min_relative_abundance, peak_min_prominence_percent)
Outputs
- Validated mass error distribution (ppm error per peak across m/z range)
- Experimental resolving power estimate (m/Δm FWHM)
- Peak assignment quality report (number of peaks with acceptable ppm error, outliers flagged)
- Calibration fit diagnostic metrics (residuals, fit quality indicator)
How to apply
Load the recalibrated FT-ICR mass spectrum (Bruker .d format) and reference calibration file using CoreMS ReadBrukerSolarix. Calculate experimental resolving power by measuring peak width at half-maximum intensity. Compare observed m/z values against the reference calibration using a mass error metric (ppm error = [(observed m/z − theoretical m/z) / theoretical m/z] × 10⁶). Inspect the mass error distribution across the m/z range to identify systematic drift or outliers; acceptable calibration typically exhibits ppm errors within ±2 ppm for high-resolution FT-ICR. Verify peak prominence thresholds and noise thresholding method settings (e.g., relative_abundance or log mode) are appropriate for the signal-to-noise ratio of the dataset. If mass errors exceed acceptable bounds or resolving power is degraded, re-run calibration with adjusted parameters (e.g., LedFort equation coefficients, number of calibrant peaks) and re-validate.
Related tools
- CoreMS (Mass spectrum I/O, calibration function implementation, resolving power calculation, and mass error metric computation) — https://github.com/EMSL-Computing/CoreMS
- Bruker Solarix (ReadBrukerSolarix) (Import and parse Bruker .d format FT-ICR transient or CompassXtract data) — https://github.com/EMSL-Computing/CoreMS
- pandas (Tabular storage and statistical analysis of mass error distributions and peak metrics)
- numpy (Numerical computation of ppm error, resolving power, and signal-to-noise ratios)
- matplotlib (Visualization of mass error distribution plots and resolving power vs. m/z trends)
Examples
from corems.transient.input.brukerSolarix import ReadBrukerSolarix; ms = ReadBrukerSolarix('tests/tests_data/ftms/ESI_NEG_SRFA.d'); ms.calibrate(ref_file='tests/tests_data/ftms/SRFA.ref'); print(f'Mass error (ppm): {ms.mass_error_ppm.mean():.2f}±{ms.mass_error_ppm.std():.2f}'); print(f'Resolving power: {ms.resolving_power_FWHM()}')
Evaluation signals
- Mass error distribution mean and standard deviation are within specification (±2 ppm or better for 12 T FT-ICR); no systematic m/z drift across the analyzed m/z range.
- Experimental resolving power meets or exceeds theoretical expectation based on ICR transient time and magnetic field strength; peak widths are consistent with the selected noise thresholding method.
- Peak prominence and signal-to-noise ratio thresholds (e.g., peak_min_prominence_percent = 1, noise_threshold_min_relative_abundance = 1) recover expected peaks without excessive false positives or negatives compared to reference spectrum.
- Calibration fit residuals (observed − predicted m/z) show no systematic polynomial structure; if a higher-order equation was used, it should not overfit.
- Recalibrated spectrum and reference calibration file align within acceptable tolerance; m/z mismatches for known reference peaks (e.g., SRFA homologue series) are < 2 ppm.
Limitations
- Recalibration validation assumes availability of a high-quality reference calibration file or set of calibrant peaks; accuracy is limited if reference data are noisy or incomplete.
- Resolving power estimates depend on accurate peak-picking and apex quadratic fitting; poor peak picking or low signal-to-noise regions may yield inflated or deflated resolving power values.
- Mass error tolerances (ppm thresholds) are instrument-dependent and may vary with magnetic field strength, transient duration, and sample composition; the ±2 ppm threshold is representative for 12 T but may not generalize to other configurations.
- Systematic calibration drift caused by temperature fluctuations, instrumental aging, or sample-dependent space-charge effects may not be fully captured by a global polynomial calibration function.
- No changelog is available in the CoreMS repository; version-to-version changes in calibration algorithms or mass error calculation methods are not explicitly documented, limiting reproducibility across CoreMS versions.
Evidence
- [other] How does SearchMolecularFormulas assign molecular formulas to detected peaks in a recalibrated FT-ICR mass spectrum using 12 T field-strength parameters?: "research_question: How does SearchMolecularFormulas assign molecular formulas to detected peaks in a recalibrated FT-ICR mass spectrum using 12 T field-strength parameters?"
- [other] Perform mass calibration with calibration functions (LedFord, linear, quadratic equations) and experimental resolving power calculation.: "Workflow: 3. Perform mass calibration"
- [other] SearchMolecularFormulas configures molecular search settings including mass error tolerance (min/max ppm error), element atom constraints, ionization mode, and calibration signal-to-noise threshold.: "SearchMolecularFormulas operates by configuring molecular search settings including mass error tolerance (min/max ppm error), element atom constraints (C, H, O, N, S), ionization mode (protonated,"
- [readme] CoreMS supports FT magnitude mode and provides frequency and m/z domain calibration functions.: "Frequency and m/z domain calibration functions: LedFord equation, Linear equation, Quadratic equation"
- [readme] Experimental resolving power is calculated; peak picking uses apex quadratic fitting.: "Peak picking using apex quadratic fitting, Experimental resolving power calculation"
- [other] Noise thresholding methods include relative_abundance and log modes with configurable thresholds.: "noise_threshold_method = 'relative_abundance' or 'log'; MSParameters.mass_spectrum.noise_threshold_min_relative_abundance = 1; MSParameters.ms_peak.peak_min_prominence_percent = 1"
- [readme] Bruker Solarix transients support FT magnitude mode only in CoreMS input formats.: "Bruker Solarix transients, ser and fid (FT magnitude mode only)"
- [readme] CoreMS data structures are designed with intuitive mass-spectrometric hierarchical structure for organized access to data and calculations.: "The data structures were designed with an intuitive, mass spectrometric hierarchical structure, thus allowing organized and easy access to the data and calculations."