Outlier detection qc sample ratio analysis

Skill HolobiomicsLab/asb-skill-collections/packs/metabolomics/lc-ms/skills/outlier-detection-qc-sample-ratio-analysis

Use when after building a SummarizedExperiment object from metabolomics LC-MS data with QC and Study Sample types defined, when you need to identify QC samples with aberrant Compound/Internal Standard ratios (indicating instrument drift, matrix effects, or sample degradation) and Study Samples with.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill outlier-detection-qc-sample-ratio-analysis

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 14 stars14 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

8.0 KB, ~1.3k tokens by cl100k_base, as published. Nobody here has run it

outlier-detection-qc-sample-ratio-analysis

Summary

Detects and flags outlier Quality Control (QC) samples in metabolomics datasets by analyzing Compound/Internal Standard ratios using statistical tests, and simultaneously identifies mis-injected Study Samples via Internal Standard area anomalies. This filtering step removes unreliable samples before downstream reporting and interpretation.

When to use

Apply this skill after building a SummarizedExperiment object from metabolomics LC-MS data with QC and Study Sample types defined, when you need to identify QC samples with aberrant Compound/Internal Standard ratios (indicating instrument drift, matrix effects, or sample degradation) and Study Samples with anomalous Internal Standard areas (indicating injection or instrumental failures) before concentration estimation or compound reliability assessment.

When NOT to use

  • When QC samples are not available in the dataset (the method requires QC replicates to establish normal ratio distribution).
  • When Internal Standards have not been assigned to compounds prior to doAnalysis() execution.
  • When the SummarizedExperiment object lacks sample type annotations (must distinguish QC from Study Samples).

Inputs

  • SummarizedExperiment object with assay containing raw compound and internal standard peak areas
  • Defined sample type annotations (QC, Study Sample, Calibration, Background)
  • Internal Standard assignments per compound

Outputs

  • SummarizedExperiment object with colData$use column (TRUE/FALSE) indicating sample reliability
  • Flagged outlier QC sample identifiers and their Compound/Internal Standard ratios
  • Flagged mis-injected Study Sample identifiers and their Internal Standard areas
  • Diagnostic summary table of outliers with statistical test results

How to apply

Load the prepared SummarizedExperiment into R and call doAnalysis() with removeOutliers=TRUE to activate outlier detection. The function calculates Compound/Internal Standard ratios for all samples, then applies the Rosner Test (a statistical outlier detection method) on QC sample ratios to flag statistical outliers. Simultaneously, it examines Internal Standard areas in Study Samples to detect mis-injections. Extract flagged samples from the result using colData(exp)$use==FALSE to retrieve outlier/mis-injected samples. Set the qcPercentage threshold (typically 80) to control sensitivity of QC flagging. Rationale: QC samples should cluster tightly in ratio space; large deviations indicate systematic problems affecting data quality, while Study Sample Internal Standard area anomalies suggest sample-specific injection or detection failures that invalidate that sample's measurements.

Related tools

Examples

exp <- doAnalysis(exp = exp, removeOutliers=TRUE, qcPercentage=80); outlier_samples <- exp[, !exp$use]; print(colData(outlier_samples)[c('aliquot', 'type')])

Evaluation signals

  • colData(exp)$use contains only TRUE/FALSE values with no missing entries after doAnalysis() execution
  • Flagged outlier QC samples have Compound/Internal Standard ratios that deviate >2–3 standard deviations from the median QC ratio (verify via diagnostic plots)
  • Flagged Study Samples have Internal Standard areas below or above expected range relative to batch median (inspect aliquotPlot output)
  • Summary statistics show qcPercentage threshold (e.g., 80%) and count of removed samples; retained QC samples show reduced RSDQC (Relative Standard Deviation) relative to input
  • Diagnostic PCA plots show improved clustering and reduced outlier separation after outlier removal

Limitations

  • Rosner Test assumes approximately normal distribution of QC ratios; severe non-normality (e.g., bimodal distributions from two instrument states) may reduce outlier detection sensitivity.
  • Method requires sufficient QC replicates (typically ≥5 per batch) to establish reliable baseline; small QC cohorts may incorrectly flag normal biological or technical variation.
  • Internal Standard area thresholds are fixed per batch; compounds or samples with genuine but extreme (non-pathological) Internal Standard values may be over-flagged.
  • Does not account for time-series drift within a batch; if instrument performance degrades monotonically, late QC samples may not be flagged if they remain within Rosner Test bounds.
  • Manual override via colData(exp)$use is possible but requires domain expertise; users unfamiliar with metabolomics QC interpretation may retain unreliable or remove valid samples.

Evidence

  • [other] Outlier QC detection by Compound/Internal Standard ratio: "The package tests samples for outliers, specifically for (Pooled) Quality Control (QC) samples using their Compound / Internal Standard ratio"
  • [other] Study Sample mis-injection flagging via Internal Standard areas: "Study Samples are tested for mis-injections using their Internal Standard areas"
  • [readme] doAnalysis function with removeOutliers parameter: "The doAnalysis function will perform the following steps: 1. Calculate the ratio between the compounds and assigned internal standards"
  • [readme] Rosner Test for statistical outlier detection: "For samples, this is based on the outcome of the Rosner Test, which tests for statistical outliers in QC samples."
  • [readme] use column for sample retention/flagging: "mzQuality adds a column called use in both the rowData and colData slots of the SummarizedExperiment. These contain either a TRUE or FALSE value, indicating if the compound or sample is"
  • [other] qcPercentage threshold parameter: "doAnalysis is called with parameters removeOutliers=TRUE, useWithinBatch=TRUE, removeBadCompounds=TRUE, qcPercentage=80, backgroundPercentage=40, and nonReportableRSD=30 thresholds"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 326,852. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.