Ms2 spectra tic filtering
Skill HolobiomicsLab/asb-skill-collections/packs/metabolomics/lc-ms/skills/ms2-spectra-tic-filtering
Use when after concatenating replicate MS/MS spectra for each precursor feature (m/z and retention time), use this skill when you have multiple replicate scans per feature and need to reduce spectral count while preserving the highest-intensity, most-reliable spectra.From its SKILL.md
npx -y skills add HolobiomicsLab/asb-skill-collections --skill ms2-spectra-tic-filteringAssembled from the repository path, not quoted from the project. Check it against their README if it does not work.
One thing to look at
- 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.
What its file declares
Copied from the file, not written here
The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.
SKILL.md
7.7 KB, ~1.4k tokens by cl100k_base, as published. Nobody here has run it
ms2-spectra-tic-filtering
Summary
Filter tandem mass spectrometry replicate spectra by retaining only those with Total Ion Current (TIC) in the top x% (typically 80%) of the distribution for a given precursor feature. This reduces spectral redundancy and noise before consensus spectrum generation and fragment frequency calculation.
When to use
After concatenating replicate MS/MS spectra for each precursor feature (m/z and retention time), use this skill when you have multiple replicate scans per feature and need to reduce spectral count while preserving the highest-intensity, most-reliable spectra. Apply it before intra-spectrum fragment grouping and consensus spectrum generation to focus on signal-rich replicates.
When NOT to use
- Input spectra have already been quality-filtered by TIC or intensity threshold upstream.
- All replicate spectra for a feature must be retained for downstream statistical analyses (e.g., replicate consistency assessment).
- The dataset contains single-scan (non-replicate) spectra per feature; TIC filtering will not reduce spectrum count meaningfully.
Inputs
- Concatenated replicate MS/MS spectra (Spectra object) from preprocessing step
- Preprocessed spectra list (l1) containing all features with replicate scans
- Folder path containing mzML files and feature statistics
- Top TIC percentage threshold (scalar, 0–1; typically 0.8)
Outputs
- Filtered Spectra object (sps_top_tic_2) containing only top x% TIC spectra per feature
- Data frame (df) with before/after spectrum counts per feature
- Grouped fragment peaks with merged m/z values and summed intensities within mass tolerance
How to apply
Load the concatenated replicate spectra list (Spectra object) for all features from the preprocessing step. Call extract_raw_spectra() with a top TIC threshold parameter (typically 0.8 for 80th percentile). The function ranks spectra for each feature by their total ion current, selects only those above the cutoff, and returns a filtered Spectra object and a data frame showing before/after spectrum counts per feature. Verify the filtering by comparing reported spectrum counts: for example, feature 1982 should reduce from 83 to 66 spectra, and feature 872 from 43 to 34 spectra when using the 80% TIC threshold. The mass tolerance parameter (default 0.05 Da) is applied during intra-spectrum fragment grouping that occurs concurrently with TIC filtering.
Related tools
- Spectra (S4 container for storing and manipulating MS/MS spectra objects; peaksData() extracts fragment m/z and intensity pairs for verification)
- dures (Provides extract_raw_spectra() function that implements top x% TIC filtering and intra-spectrum fragment grouping) — https://github.com/BiosystemEngineeringLab-IITB/dures
- data.table (Handles before/after spectrum count tabulation and filtering output)
- dplyr (Data frame manipulation for filtering and summarizing spectrum counts per feature)
Examples
l2 = extract_raw_spectra(folder_path = folder_path, l1, 0.05, 0.8)
Evaluation signals
- Spectrum count reduction per feature matches expected values: verify that feature 1982 reduces from 83→66 and feature 872 from 43→34 when using 80% TIC cutoff.
- All remaining spectra have TIC values ≥ the calculated threshold (80th percentile) for their feature.
- Output Spectra object contains no duplicate scans and maintains correct feature-to-spectrum associations.
- Intra-spectrum fragment grouping (mass tolerance 0.05 Da) is successfully applied: fragments merged by m/z mean, intensities summed; verify fragment count reduction in filtered output.
- Data frame output has one row per feature with columns: feature_id, spectra_before, spectra_after; no missing values.
Limitations
- TIC filtering is sensitive to the choice of percentile threshold (e.g., 80% vs. 90%); no universal optimal value is recommended; users should tune using Pareto front analysis (see dures-vignette-tuning).
- Features with very few replicate spectra (<3) may be reduced to 0 spectra if all fall below the TIC cutoff; such features should be flagged or excluded.
- TIC filtering assumes replicate spectra have comparable ionization efficiency and detector response; biased MS acquisition (e.g., time-dependent signal decay) can distort TIC distributions.
- Mass tolerance parameter (0.05 Da default) is applied during fragment grouping concurrently with TIC filtering; misspecification will affect both fragment counts and overall downstream results.
Evidence
- [other] Does applying a top 80% TIC selection filter reduce the per-feature spectrum counts from 83 to 66 for feature 1982 and from 43 to 34 for feature 872 in test_1?: "Does applying a top 80% TIC selection filter reduce the per-feature spectrum counts from 83 to 66 for feature 1982 and from 43 to 34 for feature 872"
- [other] Top 80% TIC cutoff reduced spectra counts from 83 to 66 for feature 1982 and from 43 to 34 for feature 872.: "Top 80% TIC cutoff reduced spectra counts from 83 to 66 for feature 1982 and from 43 to 34 for feature 872"
- [other] Call extract_raw_spectra() with parameters: folder_path, l1, mass tolerance 0.05 Da, and top TIC threshold 0.8 (80%).: "Call extract_raw_spectra() with parameters: folder_path, l1, mass tolerance 0.05 Da, and top TIC threshold 0.8 (80%)"
- [methods] In the second step, we will use
l1from the previous step as input to: 1. Extract the top x% TIC spectra, and 2. Group fragments within a specified mass tolerance: "Extract the top x% TIC spectra, and 2. Group fragments within a specified mass tolerance" - [readme] This step extracts the top 80% TIC spectra and groups fragments within a given mass tolerance: "This step extracts the top 80% TIC spectra and groups fragments within a given mass tolerance"
- [readme] l2 = extract_raw_spectra(folder_path = folder_path, l1_subset, 0.05, 0.8): "l2 = extract_raw_spectra(folder_path = folder_path, l1_subset, 0.05, 0.8)"
What ships with it
Read from the repository
Just SKILL.md. No reference files, no scripts.