Lcms peak intensity filtering

Skill HolobiomicsLab/asb-skill-collections/packs/metabolomics/lc-ms/skills/lcms-peak-intensity-filtering

Use when after XCMS peak picking, alignment, and grouping when you have identified putative incorporations (via PuInc_seeker) or base-peak isotopologue candidates and need to exclude low-intensity peaks that are likely noise or instrument artifacts.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill lcms-peak-intensity-filtering

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.2 KB, ~1.4k tokens by cl100k_base, as published. Nobody here has run it

lcms-peak-intensity-filtering

Summary

Filter LC/MS-detected peaks by minimum intensity threshold to enrich signal-to-noise ratio and reduce false positives in stable isotope labelling detection workflows. This skill applies absolute intensity cutoffs to putative incorporations and base-peak isotopologue candidates downstream of peak picking and alignment.

When to use

Apply this skill after XCMS peak picking, alignment, and grouping when you have identified putative incorporations (via PuInc_seeker) or base-peak isotopologue candidates and need to exclude low-intensity peaks that are likely noise or instrument artifacts. Use it when your LC/MS dataset exhibits variable background signal and you want to focus on metabolites with robust signal strength relative to your instrument's detection limit.

When NOT to use

  • Input is already a curated metabolite reference database or in silico spectral library (peaks are not from your experimental LC/MS run)
  • You are performing untargeted discovery on samples with extremely low metabolite abundance where even weak peaks may represent true biology
  • Intensity values are already normalized (e.g., by total ion current or internal standard) and do not reflect absolute detector signal

Inputs

  • XCMS feature table (XCMSet object) after peak picking, alignment, and grouping
  • PuInc_seeker output object (putative incorporations with fold-change and p-value annotations)
  • m/z values, retention times, and intensity measurements from aligned LC/MS runs

Outputs

  • Filtered PuInc_seeker result object with low-intensity putative incorporations excluded
  • basepeak_finder result object (geoRge object) containing base-peak isotopologue pairs meeting intensity thresholds
  • Subset of features with m/z, intensity, and isotope-pair annotations above threshold

How to apply

Establish two intensity thresholds tuned to your LC/MS platform and sample preparation: (1) a putative incorporation intensity limit (e.g., 4000 counts) applied during PuInc_seeker to filter candidate labeled/unlabeled isotopologues, and (2) a base-peak minimum intensity threshold (e.g., 2000 counts) applied during basepeak_finder to validate that identified base peaks meet minimum signal abundance. Both thresholds should be derived from your instrument's noise floor and blank samples; set them conservatively to retain true metabolite signal while eliminating instrumental noise. The rationale is that low-intensity peaks are prone to mass accuracy drift and unstable isotope-pair detection, making them unreliable for downstream identification and quantification.

Related tools

Examples

s2 <- basepeak_finder(PuIncR = s1, XCMSet = mtbls213, UL.atomM=12.0, L.atomM=13.003355, ppm.s=6.5, Basepeak.minInt=2000)

Evaluation signals

  • Filtered output contains no peaks with intensity below the specified threshold (e.g., no base peaks < 2000 counts)
  • Number of retained features is reduced by a reasonable proportion (typically 30–60%) relative to unfiltered input, indicating effective noise suppression without over-filtering
  • Retained base-peak isotopologue pairs maintain consistent mass accuracy (within 6.5 ppm tolerance) and intensity ratios expected for labeled/unlabeled carbon-13 pairs
  • Downstream database_query hits and metabolite identifications show improved specificity (fewer false positives) compared to unfiltered runs
  • m/z and intensity distributions of filtered peaks align with expected metabolite mass ranges and instrument sensitivity

Limitations

  • Intensity thresholds are dataset and instrument-specific; thresholds derived from mtbls213 may not transfer to different LC/MS platforms, ionization modes, or sample matrices without reoptimization
  • Filtering by absolute intensity assumes uniform detector response across m/z range; non-linear or m/z-dependent sensitivity bias may cause systematic loss of low-abundance metabolites in certain mass windows
  • Threshold selection requires prior knowledge of noise floor; if blank/negative control intensities are not characterized beforehand, threshold setting may be arbitrary or too stringent/permissive
  • geoRge 1.0 reduced function arguments for usability; verify that your version's default or user-specified intensity parameters match your experimental design

Evidence

  • [intro] basepeak_finder function to identify base peaks with specified mass accuracy and intensity thresholds: "basepeak_finder function to identify base peaks with specified mass accuracy and intensity thresholds"
  • [methods] unlabelled atomic mass 12.0, labelled atomic mass 13.003355, mass accuracy tolerance 6.5 ppm, and base-peak minimum intensity threshold 2000: "unlabelled atomic mass 12.0, labelled atomic mass 13.003355, mass accuracy tolerance 6.5 ppm, and base-peak minimum intensity threshold 2000"
  • [intro] Base peak minimum intensity of 2000: "Base peak minimum intensity of 2000"
  • [intro] Putative incorporation intensity limit of 4000: "Putative incorporation intensity limit of 4000"
  • [methods] s2 <- basepeak_finder(PuIncR=s1,XCMSet=mtbls213,ULtag="CELL_Glc12",Ltag="CELL_Glc13",sep.pos="f",UL.atomM=12.0,L.atomM=13.003355,ppm.s=6.5,Basepeak.minInt=2000): "s2 <- basepeak_finder(PuIncR=s1,XCMSet=mtbls213,ULtag="CELL_Glc12",Ltag="CELL_Glc13",sep.pos="f",UL.atomM=12.0,L.atomM=13.003355,ppm.s=6.5,Basepeak.minInt=2000)"
  • [readme] Same functions, less arguments. I have updated the functions so they are less tiring to use.: "Same functions, less arguments. I have updated the functions so they are less tiring to use."

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.