Chromatographic peak annotation visualization

Skill HolobiomicsLab/asb-skill-collections/packs/metabolomics/lc-ms/skills/chromatographic-peak-annotation-visualization

Curated, evidence-grounded skill and software-tool collections for scientific AI agents, generated by the AgenticScienceBuilder

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill chromatographic-peak-annotation-visualization

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 14 stars14 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its author says it does

Copied from the file, not written here

Use when after running tardisPeaks() with screening_mode=TRUE on centroided .mzML LC-MS data, when you need to visually inspect whether the 10 target compounds (internal standards and endogenous metabolites) were correctly detected within their expected m/z and retention time windows.

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

8.8 KB, as published. Nobody here has run it

Chromatographic Peak Annotation and Visualization

Summary

Generate and inspect extracted ion chromatogram (EIC) plots with annotated peaks for targeted LC-MS compounds, enabling visual quality control of peak detection, integration, and retention time alignment across sample batches. This skill bridges automated peak detection with human-interpretable diagnostic plots for targeted metabolomics and lipidomics workflows.

When to use

After running tardisPeaks() with screening_mode=TRUE on centroided .mzML LC-MS data, when you need to visually inspect whether the 10 target compounds (internal standards and endogenous metabolites) were correctly detected within their expected m/z and retention time windows. Use this skill to generate diagnostic QC plots before proceeding to quantitative integration in non-screening mode, especially when validating a new target list or batch of samples.

When NOT to use

  • Your input data is already in profile (non-centroided) mode; TARDIS requires centroided .mzML files.
  • You are performing untargeted or discovery-mode metabolomics without a predefined target list; this skill is designed for targeted screening only.
  • You have already obtained quantitative integration results and need statistical comparison; use this skill earlier in the workflow, during the screening phase.

Inputs

  • centroided .mzML LC-MS runs (14+ runs typical)
  • target list data.frame with columns: compound ID, compound name, theoretical m/z, expected retention time (minutes), ionization polarity
  • Spectra objects or file paths to .mzML files loaded into TARDIS environment

Outputs

  • PNG files containing extracted ion chromatogram (EIC) plots with annotated peaks for each target compound
  • plots saved to output/screening/Diagnostic_QCs_Batch_N/ folder
  • visual quality control diagnostic plots suitable for inspection and reporting

How to apply

Execute tardisPeaks() with screening_mode=TRUE on your loaded Spectra objects and target list data.frame (containing compound ID, name, theoretical m/z, expected RT in minutes, and ionization polarity). The function automatically applies polarity filtering and generates EIC plots for each of the target compounds, saving individual PNG files to the output/screening/Diagnostic_QCs_Batch_N/ folder. Inspect the resulting plots to verify (1) peak visibility within the defined m/z and RT windows, (2) peak annotation accuracy and integration boundaries, and (3) consistency of peak shape and retention time across replicates. The visualization step is essential for detecting method failures (missing signals, interfering peaks, retention time drift) before committing to full quantitative analysis.

Related tools

  • TARDIS (R package that executes tardisPeaks() function with screening_mode=TRUE to detect peaks and generate EIC plots for all target compounds) — https://github.com/pablovgd/TARDIS
  • Spectra (Bioconductor package for loading and representing MS data as Spectra objects, the native input format for TARDIS)
  • xcms (Provides retention time correction algorithms used internally by TARDIS for RT alignment)
  • MsExperiment (Alternative input container for MS data to TARDIS; can be used instead of file paths)
  • ProteoWizard (MSConvert) (Converts vendor-specific LC-MS raw files to .mzML format and applies centroiding prior to TARDIS input)

Examples

library(TARDIS); results <- tardisPeaks(mzml_files = list.files(path='./data', pattern='\.mzML$', full.names=TRUE), target_list = targets_df, screening_mode = TRUE, output_folder = './output/screening')

Evaluation signals

  • All 10 target compounds (5 internal standards + 5 endogenous metabolites) have corresponding PNG files in the output/screening/Diagnostic_QCs_Batch_N/ folder.
  • Each EIC plot shows a clearly annotated peak within the expected m/z ± tolerance and retention time ± tolerance window defined in the target list.
  • Peak annotation includes visible integration boundaries and does not overlap with unexpected peaks in the chromatographic background.
  • Retention time consistency across replicates is visually confirmed; peaks for the same compound cluster within a narrow RT range (typically < 0.5 min drift across a batch).
  • Diagnostic plots are suitable for inclusion in QC reports and enable rapid identification of compounds with missing or degraded signals before proceeding to quantitative integration.

Limitations

  • Screening-mode visualization does not provide quantitative metrics (AUC, max intensity, SNR, peak correlation); these require a separate non-screening-mode run with tardisPeaks(screening_mode=FALSE).
  • EIC plot quality and interpretability depend on the quality of centroiding and the accuracy of the input target list (m/z, RT, polarity); incorrect target parameters will produce uninformative or misleading plots.
  • Visual inspection of PNG files is a manual, subjective step; no automated quality scoring is performed at the visualization stage. Formal acceptance criteria must be defined by the analyst.
  • The package requires R ≥ 4.4.0 and BiocManager 3.20 with specific dependency versions; installation can be prone to timeout issues on slow connections.

Evidence

  • [other] Generate extracted ion chromatogram (EIC) plots for each of the 10 targets with peak annotation and save as individual PNG files to the output/screening/Diagnostic_QCs_Batch_1/ folder for visual inspection of target detection.: "Generate extracted ion chromatogram (EIC) plots for each of the 10 targets with peak annotation and save as individual PNG files to the output/screening/Diagnostic_QCs_Batch_1/ folder for visual"
  • [other] tardisPeaks() in screening mode generates EIC plots for all 10 targets that are saved to the output folder and can be inspected, with resulting diagnostic plots for QC runs showing peak detection and integration for each component.: "tardisPeaks() in screening mode generates EIC plots for all 10 targets that are saved to the output folder and can be inspected, with resulting diagnostic plots for QC runs"
  • [other] Execute tardisPeaks() function with screening_mode=TRUE to detect peaks and screen for target compound visibility within defined m/z and retention time windows across all runs, automatically applying polarity filtering.: "Execute tardisPeaks() function with screening_mode=TRUE to detect peaks and screen for target compound visibility within defined m/z and retention time windows"
  • [intro] Polarity filtering is done within TARDIS, so no polarity subsetting has to be performed: "Polarity filtering is done within TARDIS, so no polarity subsetting has to be performed"
  • [results] The resulting EICs are again saved in the output folder and can be inspected: "The resulting EICs are again saved in the output folder and can be inspected"
  • [intro] Input files need to be converted to the .mzML format and have to be centroided: "Input files need to be converted to the .mzML format and have to be centroided"
  • [intro] compound ID, a unique identifier; A compound Name; Theoretical or measured m/z; Expected RT (in minutes); A column that indicates the polarity: "compound ID, a unique identifier; A compound Name; Theoretical or measured m/z; Expected RT (in minutes); A column that indicates the polarity"