Mz retention time tolerance parameter configuration

Skill HolobiomicsLab/asb-skill-collections/packs/metabolomics/direct-infusion/skills/mz-retention-time-tolerance-parameter-configuration

Curated, evidence-grounded skill and software-tool collections for scientific AI agents, generated by the AgenticScienceBuilder

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill mz-retention-time-tolerance-parameter-configuration

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 14 stars14 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its author says it does

Copied from the file, not written here

Use when when invoking Asari to process centroid mzML files for the first time in a PCPFM experiment, or when RT and m/z accuracy characteristics of your LC-MS instrument differ from the pipeline defaults (e.

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.6 KB, as published. Nobody here has run it

mz-retention-time-tolerance-parameter-configuration

Summary

Configuration of mass-to-charge (m/z) and retention time (RT) tolerance parameters for feature grouping in Asari LC-MS feature extraction. These parameters define the maximum acceptable deviations when clustering detected ions into putative metabolite features across a sample cohort.

When to use

When invoking Asari to process centroid mzML files for the first time in a PCPFM experiment, or when RT and m/z accuracy characteristics of your LC-MS instrument differ from the pipeline defaults (e.g., instruments with lower mass resolution, longer RT drift, or non-standard chromatography). Parameter tuning is warranted if you observe either excessive feature fragmentation (same metabolite split across multiple feature rows) or over-merging (unrelated ions grouped into a single feature).

When NOT to use

  • Input data are already in feature table format (i.e., features have already been grouped and aligned). These parameters apply only during the initial mzML-to-feature-table conversion step.
  • Working with non-LC-MS data (e.g., GC-MS, direct infusion MS) where retention time is not a meaningful dimension or where different grouping logic applies.
  • Instrument specifications are unknown and cannot be estimated from prior calibration data or manufacturer documentation; in such cases, rely on default values and validate results post-hoc rather than attempting blind parameter optimization.

Inputs

  • centroid mzML files (in converted_acquisitions subdirectory)
  • PCPFM experiment object with inferred ionization mode (positive or negative)
  • LC-MS instrument specifications (mass accuracy, chromatographic reproducibility)

Outputs

  • feature grouping configuration (m/z and RT tolerance parameters passed to Asari)
  • full feature table with all detected features grouped according to specified tolerances
  • preferred feature table with quality-filtered features grouped according to specified tolerances

How to apply

Asari accepts two key tolerance parameters during invocation: (1) m/z tolerance, specified in parts-per-million (ppm), which controls the maximum mass deviation allowed when grouping ions of the same putative feature across samples; (2) retention time tolerance, specified in seconds, which defines the maximum RT shift permitted for an ion to be assigned to an existing feature group. The default values are 5 ppm m/z tolerance and 2 second RT tolerance for feature grouping. These defaults are optimized for typical high-resolution LC-MS platforms. Adjustment should be made based on your instrument's demonstrated mass accuracy and chromatographic reproducibility: stricter tolerances (e.g., 3 ppm, 1 second) reduce false merging but may fragment true features; looser tolerances (e.g., 10 ppm, 5 seconds) increase feature recovery but risk grouping unrelated ions. Rationale: m/z tolerance must accommodate instrument mass error, which typically ranges from 1–5 ppm on modern Orbitraps but can be 10+ ppm on lower-resolution platforms; RT tolerance must account for inter-sample chromatographic drift and column performance degradation over a batch run.

Related tools

Evaluation signals

  • Feature table row count and feature density (median features per sample) are stable across re-runs with identical parameters and should increase or remain stable when tolerances are relaxed, decrease when tightened.
  • Manual inspection of a representative set of feature peak shapes using Asari's visual dashboard confirms that grouped ions share consistent m/z and RT coordinates within the specified tolerances and are not artefactually merged.
  • Replicate sample correlation improves (e.g., Pearson r > 0.9 for technical replicates) when parameters are optimized, indicating reduced feature fragmentation and spurious merging.
  • Quality metrics reported in the preferred feature table (e.g., signal-to-noise, feature completeness across samples) do not degrade when parameters are adjusted within a reasonable range (±50% of defaults).
  • Downstream annotation results (number of matched MS1 or MS2 identifications per feature) do not decrease, suggesting features remain biologically coherent after grouping.

Limitations

  • Default 5 ppm m/z and 2 second RT tolerances are optimized for high-resolution Orbitrap and similar modern instruments; lower-resolution or time-of-flight instruments may require significantly larger m/z tolerances (e.g., 10–20 ppm) to achieve adequate feature grouping, risking over-merging.
  • RT tolerance is sensitive to chromatographic drift and batch effects; a global fixed value may be inadequate for very long sample runs or instruments with significant inter-batch RT shifts. Internal spike-in standards for QC support is to be implemented but currently unavailable.
  • No automated method for deriving optimal tolerances from instrument QC data is provided; practitioners must rely on instrument specifications, prior validation studies, or manual tuning based on biological replicability.
  • Parameter optimization requires iterative trial-and-error or access to ground-truth spike-in or reference standards, which may not be available for all compound classes or experimental contexts.

Evidence

  • [other] Invoke Asari with the inferred ionization mode on the converted_acquisitions subdirectory containing centroid .mzML files, using default parameters (5 ppm m/z tolerance, 2 second retention time tolerance for feature grouping).: "using default parameters (5 ppm m/z tolerance, 2 second retention time tolerance for feature grouping)"
  • [other] Asari outputs a full feature table containing all detected features and a preferred feature table with quality-filtered features, both stored in the asari_results directory.: "Asari outputs a full feature table containing all detected features and a preferred feature table with quality-filtered features"
  • [readme] process mzML data to feature tables (Asari): "process mzML data to feature tables (Asari)"