Ce ms migration time measurement

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/ce-ms-migration-time-measurement

Use when when processing raw CE-MS data and need to establish a baseline migration time scale before transforming to effective mobility.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill ce-ms-migration-time-measurement

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

8.4 KB, ~1.5k tokens by cl100k_base, as published. Nobody here has run it

CE-MS migration time measurement

License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->

Summary

Extract and record migration times (retention times) of analytes from capillary electrophoresis–mass spectrometry (CE-MS) datasets, serving as the primary input for subsequent effective mobility transformation. Migration times vary with electroosmotic flow fluctuations and must be precisely measured to enable calibration against EOF markers.

When to use

When processing raw CE-MS data and need to establish a baseline migration time scale before transforming to effective mobility. Specifically required when the goal is to normalize peak positions across runs with variable electroosmotic flow, or when preparing analyte data for single- or multi-marker mobility calibration using reference compounds with known effective mobilities.

When NOT to use

  • Input is already transformed to effective mobility scale — migration time measurement is a prerequisite, not a post-processing step.
  • Capillary electrophoresis–UV (CE-UV) data without MS detection — CE-UV uses different detection and quantitation workflows that do not require subsequent mobility transformation.
  • When EOF marker or reference compound migration times are unavailable — the calibration step depends on both analyte and marker migration times, so measurement of markers must be complete first.

Inputs

  • Raw CE-MS electropherogram or extracted ion chromatogram (mzML, NetCDF, or vendor-specific format)
  • Analyte peak detection list (m/z, retention time window, signal intensity)
  • Experimental metadata: applied voltage (U in kV), capillary length (L in mm or cm), electrical field ramp time (tR in minutes)

Outputs

  • Analyte migration time (tM or rtime) in minutes, per compound
  • Data frame with columns: compound name/ID, migration time, m/z, peak intensity, experimental run ID

How to apply

Load the CE-MS dataset (typically from msdata package or vendor-supplied files) and identify the analyte peak of interest within the extracted ion chromatogram or electropherogram. Record the migration time (tM or rtime) as the time at which the analyte signal reaches its maximum intensity. Measure this value in minutes, converting from raw instrument output if needed (e.g., from seconds to fractional minutes for consistency with calibration parameters tR in 3/60 min format). Ensure the measurement includes the full instrumental runtime context (applied voltage U, capillary length L, temperature conditions). This migration time then serves as the mandatory input to mobilityTransform() for calculation of effective mobility via the single-marker or multi-marker equations. Validate that migration times are stable and reproducible across technical replicates before proceeding to mobility transformation; high variance suggests instrumental drift or EOF instability requiring separate troubleshooting.

Related tools

  • xcms (Peak detection and feature extraction from CE-MS raw data; identifies analyte migration times in electropherograms)
  • MSnbase (Spectral data representation and manipulation; stores and accesses migration time metadata within MS objects)
  • Spectra (Unified interface for spectrum and chromatogram handling; retrieves migration times from CE-MS objects)
  • msdata (Provides CE-MS test datasets for validation and prototyping of migration time extraction workflows)
  • MobilityTransformR (Consumes extracted migration times and applies them as input to mobilityTransform() function for effective mobility calculation) — https://github.com/LiesaSalzer/MobilityTransformR

Examples

# Load CE-MS data and extract Procaine migration time; prepare for mobilityTransform
df_procaine <- data.frame(compound='Procaine', rtime=tM_procaine_mins, marker_rtime=3/60, marker_mobility=0, U=30, L=800, tR=3/60)
mobility_result <- mobilityTransform(df_procaine$rtime, marker_rtime=df_procaine$marker_rtime, marker_mobility=0, tR=3/60, U=30, L=800)

Evaluation signals

  • Migration times are recorded in consistent units (minutes) and fall within the expected instrumental runtime window (typically 0–30 min for capillary electrophoresis).
  • EOF marker migration time (e.g., Paracetamol in the reference task) is measured and present in the dataset; analyte migration times are greater than EOF marker time for positively charged species under positive voltage.
  • Migration time values are reproducible across technical replicates with coefficient of variation < 5–10%, indicating stable EOF and instrumental conditions.
  • Both analyte and reference marker migration times can be successfully passed to mobilityTransform() function without schema errors or missing-value flags.
  • Extracted migration times align with expected peak positions in the mass trace visualization and match vendor software or literature values for known reference compounds.

Limitations

  • Migration times fluctuate due to electroosmotic flow variations across runs; effective mobility transformation is specifically designed to compensate for this drift, meaning migration time alone is not a stable metric for cross-run peak alignment.
  • Measurement accuracy depends on peak detection algorithm quality; co-eluting peaks or low signal-to-noise ratios can produce unreliable migration times.
  • No R implementation existed for CE-MS mobility transformation until MobilityTransformR; legacy CE-UV tools or non-R software (e.g., ROMANCE) may not be compatible with standard R data frame formats.
  • Migration time measurement from raw instrument files requires format-specific parsers (mzML, NetCDF); proprietary vendor formats may require additional preprocessing or conversion steps.

Evidence

  • [intro] Migration time serves as primary input to mobilityTransform function: "Invoke MobilityTransformR's mobilityTransform function with the calibration parameters: tR (reference time) = 3/60 minutes, U (applied voltage) = +30 kV, and L (capillary length) = 800 cm."
  • [intro] Migration times show fluctuations due to EOF variation, necessitating transformation: "the effective mobility µ_eff of a compound remains stable in the same electrophoretic system. The use of an effective mobility scale instead of a migration time scale circumvents the drawback of MT"
  • [intro] CE-MS mobility transformation differs from CE-UV and requires dedicated implementation: "Effective mobility transformation for CE-MS data is not as straightforward as in CE-UV and until now and to our knowledge there is no implementation in R that performs effective mobility"
  • [intro] MobilityTransformR consolidates positive and negative mobilities in single output: "However, the outputs are two separate files, each for positive and negative mobilities... the output will be a single file containing both, the positive and negative effective mobilities"
  • [readme] Installation and access to CE-MS test data for validation: "if (!requireNamespace("BiocManager", quietly = TRUE)) install.packages("BiocManager"); BiocManager::install("MobilityTransformR")"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.