Peak m z recalibration

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/peak-m-z-recalibration

Use when after peak detection when you have a table of detected peaks with m/z values and need to improve mass accuracy for downstream annotation.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill peak-m-z-recalibration

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.6 KB, ~1.2k tokens by cl100k_base, as published. Nobody here has run it

peak-m/z-recalibration

License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->

Summary

Recursive mass correction refines m/z accuracy of detected LC/HRMS peaks by recalibrating their mass-to-charge coordinates using internal reference standards or lock masses. This step is applied post-detection to improve mass accuracy metrics across large untargeted metabolomics datasets.

When to use

Apply this skill after peak detection when you have a table of detected peaks with m/z values and need to improve mass accuracy for downstream annotation. Use it in untargeted LC/HRMS population-scale studies (n > 500) where systematic mass drift or calibration error may affect m/z precision across multiple batches or acquisitions.

When NOT to use

  • Input peaks are already from a targeted method with locked or fixed m/z windows — recursive correction may introduce unnecessary noise.
  • Untargeted data were acquired on low-resolution instruments (nominal mass accuracy) — correction tolerances and reference lock mass precision may not justify the algorithm.
  • No internal reference standards or endogenous markers are available in the dataset — the algorithm requires calibration anchors to function.

Inputs

  • Detected peaks table (from peak detection stage) containing m/z values, retention times, and peak properties
  • Mass spectrometry raw data (mzXML, mzML, or netCDF format) or extracted ion chromatogram (EIC) data
  • Internal reference standards or lock mass m/z values (optional; endogenous markers may substitute)

Outputs

  • Corrected peak table with recalibrated m/z values
  • Mass accuracy metrics (pre- and post-correction ppm error, calibration statistics)
  • Calibration residual data for quality assessment

How to apply

Load the detected peaks table containing m/z values and peak properties from the prior peak detection stage. Apply the recursive mass correction algorithm implemented in IDSL.IPA, which recalibrates m/z coordinates using internal reference standards (lock masses) or endogenous reference markers available in the dataset. The algorithm iteratively refines mass calibration to minimize systematic error. Generate a corrected peak table with updated m/z coordinates and compare pre- and post-correction m/z accuracy metrics (e.g., ppm error distribution, mass calibration residuals) to verify improvement. Export the final corrected peak dataset for downstream retention time correction and peak annotation workflows.

Related tools

  • IDSL.IPA (Provides the recursive mass correction algorithm and integration with full LC/HRMS peak processing pipeline (EIC generation, peak detection, property evaluation, retention time correction, and annotation)) — https://github.com/idslme/IDSL.IPA
  • R (Language and runtime environment for executing IDSL.IPA package and recursive mass correction workflow)

Examples

library(IDSL.IPA); IPA_workflow("path/to/IPA_parameters.xlsx")

Evaluation signals

  • Pre- and post-correction m/z accuracy distribution: post-correction ppm error should be narrower and centered closer to zero than pre-correction values.
  • Calibration residuals: systematic mass drift should be minimized; residuals should not show batch or time-dependent patterns.
  • Mass calibration statistics (e.g., RMSE, max error): quantitative improvement in mass precision across the m/z range.
  • Downstream peak alignment and annotation quality: correctly recalibrated m/z values should improve alignment rates and reduce false monoisotopic peak assignments.
  • Isotope pattern coherence: m/z differences between detected isotopologue pairs (e.g., ¹²C/¹³C) should match theoretical mass defect after correction.

Limitations

  • Recursive mass correction depends on availability and accuracy of internal reference standards or lock masses; if reference m/z values are themselves miscalibrated, the algorithm may propagate error.
  • Performance in multi-batch studies requires endogenous reference markers (retention time correction anchors) to be present and reliably detected across all samples; sparse or variable reference detection can degrade correction fidelity.
  • The algorithm is designed for high-resolution mass spectrometry (HRMS) data; application to nominal-mass or low-resolution data may not yield meaningful improvements.
  • No changelog was found in the repository documentation, limiting visibility into algorithm refinements or known issues across IDSL.IPA versions.

Evidence

  • [other] IDSL.IPA includes a recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy of detected peaks.: "recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy"
  • [other] Load detected peaks table containing m/z values and peak properties from prior detection step. Apply recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using internal reference standards or lock masses.: "Load detected peaks table containing m/z values and peak properties from prior detection step. Apply recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using"
  • [readme] IDSL.IPA is a suite of new algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation, recursive mass correction, retention time correction across multiple batches and peak annotation.: "IDSL.IPA is a suite of new algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation, recursive mass correction, retention time correction"
  • [readme] extracts peaks for organic small molecules from untargeted liquid chromatography high resolution mass spectrometry (LC/HRMS) data in population scale projects: "extracts peaks for organic small molecules from untargeted liquid chromatography high resolution mass spectrometry (LC/HRMS) data in population scale projects"
  • [readme] Retention time correction using endogenous reference markers for multi-batch large scale studies: "Retention time correction using endogenous reference markers for multi-batch large scale studies"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.