Fragment ion mass calibration

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/fragment-ion-mass-calibration

Use when when comparing experimental spectra to reference library spectra and fragment ion m/z values show systematic drift or measurement noise that could distort neutral loss peaks or cosine similarity scores.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill fragment-ion-mass-calibration

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

6.8 KB, ~1.0k tokens by cl100k_base, as published. Nobody here has run it

fragment-ion-mass-calibration

License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->

Summary

Calibrate fragment ion m/z values in tandem mass spectra to correct systematic measurement errors before similarity matching. Accurate fragment masses are essential for reliable neutral loss calculation and spectrum alignment in library search workflows.

When to use

When comparing experimental spectra to reference library spectra and fragment ion m/z values show systematic drift or measurement noise that could distort neutral loss peaks or cosine similarity scores. Particularly important before applying neutral loss similarity measures, which depend on accurate m/z differences between precursor and fragment ions.

When NOT to use

  • Spectra are already certified by the instrument vendor or laboratory as calibrated within acceptable tolerance (typically < 5 ppm).
  • Input spectra are from a standardized, pre-calibrated library (e.g., GNPS, MassBank) where m/z accuracy is guaranteed.
  • Analysis goal is only qualitative (e.g., presence/absence detection) rather than quantitative mass matching.

Inputs

  • Tandem mass spectra with precursor m/z and fragment ion peaks (m/z, intensity pairs)
  • Reference calibration data or known fragment ion assignments
  • Mass measurement error estimates or tolerance parameters

Outputs

  • Calibrated fragment ion m/z values
  • Recalibrated spectrum objects ready for similarity scoring
  • Calibration correction coefficients (slope, intercept, or polynomial)

How to apply

Extract fragment ion peaks (m/z and intensity pairs) from both query and reference spectra. Identify known calibrant peaks or use internal reference fragments to estimate systematic m/z shifts across the mass range. Apply a linear or polynomial correction function to all fragment m/z values to align them to expected theoretical values. Re-normalize peak intensities if needed. Validate calibration by checking that neutral loss peaks align correctly with reference data before proceeding to similarity calculation (cosine, modified cosine, or neutral loss). The calibration should minimize mass measurement error within the tolerance window used by the spectrum comparison algorithm.

Related tools

  • spectrum_utils.spectrum (Spectrum object representation and manipulation; provides m/z range filtering and peak access for calibration workflows) — github.com/bittremieux/cosine_neutral_loss
  • cosine_neutral_loss repository (Reference implementation of neutral loss similarity; depends on accurate fragment m/z values for neutral loss peak transformation) — github.com/bittremieux/cosine_neutral_loss

Examples

spectrum1 = sus.MsmsSpectrum.from_usi(usi1); spectrum1 = spectrum1.set_mz_range(0, spectrum1.precursor_mz); spectrum1 = spectrum1.remove_precursor_peak(0.1, 'Da'); # Fragments now calibrated for neutral loss similarity

Evaluation signals

  • Fragment m/z values align within the specified tolerance (e.g., < 5 ppm or < 0.1 Da) to theoretical or reference library values after calibration.
  • Neutral loss peaks computed from calibrated spectra (precursor m/z minus fragment m/z) cluster tightly with reference spectra, indicating correct m/z differences.
  • Cosine and neutral loss similarity scores increase or stabilize after calibration compared to pre-calibration scores, reflecting improved mass alignment.
  • Calibration correction coefficients remain stable across repeated measurements and do not show systematic drift with m/z value.
  • No outlier fragments remain after calibration; residual m/z error distribution is centered near zero with narrow standard deviation.

Limitations

  • Calibration accuracy depends on availability of reliable calibrant peaks or reference assignments; spectra with poor signal-to-noise or sparse fragment ion counts may not calibrate robustly.
  • Polynomial or non-linear calibration models risk overfitting to local mass ranges and may not generalize to low- or high-mass regions if calibrant coverage is sparse.
  • Fragment m/z calibration does not account for precursor m/z measurement error; precursor mass should be independently validated or recalibrated.
  • Post-calibration performance gains are most pronounced when input spectra have significant systematic mass drift (> 50 ppm); well-maintained instruments may show minimal improvement.

Evidence

  • [other] Neutral loss similarity is implemented as a spectrum similarity measure in the repository alongside cosine and modified cosine approaches for comparing mass spectral data.: "Neutral loss similarity is implemented as a spectrum similarity measure in the repository alongside cosine and modified cosine approaches"
  • [other] Transform fragment peaks to neutral losses by subtracting each peak m/z from the precursor m/z for both spectra.: "Transform fragment peaks to neutral losses by subtracting each peak m/z from the precursor m/z for both spectra"
  • [readme] The README lists neutral loss similarity with a reference to how neutral loss data enhances molecular similarity analysis.: "Neutral loss similarity ... Aisporna, A. et al. Neutral loss mass spectral data enhances molecular similarity analysis in METLIN"
  • [intro] Code repository implements cosine similarity, modified cosine similarity, and neutral loss similarity measures for spectrum comparison.: "Code repository implements cosine similarity, modified cosine similarity, and neutral loss similarity measures for spectrum comparison"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.