Spectrum peak counting and reporting

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectrum-peak-counting-and-reporting

Use when when you need to quantify and compare the filtering efficacy of mutually exclusive noise-threshold methods on the same input mass spectrum, or when validating that a selected noise-filtering strategy retains an expected number of peaks for downstream molecular formula assignment.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill spectrum-peak-counting-and-reporting

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 14 stars14 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

8.6 KB, ~1.4k tokens by cl100k_base, as published. Nobody here has run it

spectrum-peak-counting-and-reporting

Summary

Count and report the number of peaks retained in a mass spectrum after applying a selected noise-threshold method (relative_abundance, signal_noise, or log mode), producing structured records of method identifier and peak counts per ionization mode for comparative evaluation.

When to use

When you need to quantify and compare the filtering efficacy of mutually exclusive noise-threshold methods on the same input mass spectrum, or when validating that a selected noise-filtering strategy retains an expected number of peaks for downstream molecular formula assignment.

When NOT to use

  • Input is a mass list that has already been noise-filtered or centroided by the instrument vendor; peak counting is post-hoc reporting, not applicable to data that lacks the raw signal intensity distribution needed to re-apply threshold criteria.
  • Analysis goal requires identification of isotopic clusters or fine structure; peak counting reports total peaks but does not distinguish monoisotopic, isotopic, or artifact peaks.
  • Spectrum has already been processed through multiple conflicting noise-threshold steps; multiple successive applications of different methods will compound filtering artifacts.

Inputs

  • Raw mass spectrum file (Bruker .d, ThermoFisher .raw, or CoreMS HDF5 format)
  • MSParameters configuration object with noise-threshold method selection
  • Noise-threshold parameters: relative_abundance minimum threshold, signal_noise ratio threshold, or log standard deviation cutoff

Outputs

  • Peak count (integer) per noise-threshold method
  • Method identifier (string: 'relative_abundance', 'signal_noise', or 'log')
  • Ionization mode label (e.g., 'ESI_NEG')
  • Structured JSON or CSV record with method name, peak count, and mode

How to apply

Load a raw mass spectrum (e.g., ESI_NEG_SRFA.d in Bruker or .raw format) using CoreMS MSParameters factory. Select one of three mutually exclusive noise-threshold methods: 'relative_abundance' (filtered by minimum relative abundance parameter), 'signal_noise' (filtered by signal-to-noise ratio threshold), or 'log' (filtered by standard deviation parameter). Apply the selected method to the loaded spectrum using CoreMS peak-filtering routines. Capture and serialize the resulting peak count, method name, and ionization mode identifier as a structured JSON or CSV record. Compare peak counts across methods to evaluate which filtering strategy best balances noise suppression and analyte retention for your analysis goal.

Related tools

  • CoreMS (Provides MSParameters factory to instantiate noise-threshold configuration, implements conditional dispatch logic for three mutually exclusive threshold methods, and applies peak-filtering routines to compute final peak counts.) — https://github.com/EMSL-Computing/CoreMS
  • pandas (Serializes peak count results and method metadata into structured DataFrames; enables export to CSV or Excel for downstream comparison.)
  • Docker (Provides containerized execution environment to ensure reproducible CoreMS-based peak counting workflows across systems.)

Examples

from corems.encapsulation.factory.parameters import MSParameters
from corems.data_source.data_source_factory import run_from_file
import json

ms_obj = run_from_file('tests/tests_data/ftms/ESI_NEG_SRFA.d', MSParameters)
for spectrum in ms_obj:
    spectrum.apply_noise_threshold(SNR_threshold=10, noise_method='signal_noise')
    result = {'method': 'signal_noise', 'peak_count': len(spectrum.peaks), 'ionization_mode': 'ESI_NEG'}
    print(json.dumps(result))

Evaluation signals

  • Peak count is a non-negative integer; verify it is ≥ 0 and ≤ total m/z centroids detected in the raw spectrum.
  • Method identifier matches exactly one of: 'relative_abundance', 'signal_noise', or 'log'; no other mode is reported.
  • Peak counts differ across the three mutually exclusive methods applied to the same input spectrum (different methods should produce different retention counts unless the spectrum is trivial).
  • Ionization mode label is correctly inherited from input spectrum metadata (e.g., 'ESI_NEG' for negative-ion ESI data).
  • JSON or CSV output conforms to expected schema: columns for method name, peak_count, ionization_mode, and optional timestamp; no missing or malformed entries.

Limitations

  • Peak count is a global statistic; it does not distinguish peak quality, confidence, or role in molecular formula assignment.
  • The three noise-threshold methods are mutually exclusive; a single spectrum can be processed under only one method at a time, preventing simultaneous multi-method evaluation within a single call.
  • Peak counting does not account for m/z calibration accuracy; miscalibrated spectra may produce artificially high or low peak counts if threshold criteria are m/z-dependent.
  • CoreMS peak-filtering routines are designed for small-molecule analysis (ESI and FT-MS); applicability to GC-MS, LC-MS, or high-resolution imaging mass spectrometry workflows is not documented in the provided evidence.

Evidence

  • [other] CoreMS provides three mutually exclusive noise threshold methods: 'relative_abundance' (filtered by minimum relative abundance parameter), 'signal_noise' (filtered by signal-to-noise ratio threshold), and 'log' (filtered by standard deviation parameter), each producing different peak retention counts for the same input spectrum.: "CoreMS provides three mutually exclusive noise threshold methods: 'relative_abundance' (filtered by minimum relative abundance parameter), 'signal_noise' (filtered by signal-to-noise ratio"
  • [other] Load mass spectrum data from ESI_NEG_SRFA.d using CoreMS MSParameters factory to instantiate noise-threshold configuration. Implement conditional dispatch logic that selects one of three mutually exclusive noise-threshold methods (COND-001, COND-002, COND-003) based on spectrum properties or user input. Apply the selected noise-threshold method to the loaded spectrum using CoreMS peak-filtering routines. Capture the resulting peak count per ionization mode and method name. Serialize the results (method identifier, peak count per mode) as a structured JSON or CSV record.: "Load mass spectrum data from ESI_NEG_SRFA.d using CoreMS MSParameters factory to instantiate noise-threshold configuration...Apply the selected noise-threshold method to the loaded spectrum using"
  • [readme] CoreMS is a comprehensive mass spectrometry framework for software development and data analysis of small molecules analysis.: "CoreMS is a comprehensive mass spectrometry framework for software development and data analysis of small molecules analysis"
  • [other] from corems.encapsulation.factory.parameters import MSParameters: "from corems.encapsulation.factory.parameters import MSParameters"
  • [readme] Bruker Solarix (CompassXtract), Bruker Solarix transients, ser and fid (FT magnitude mode only), ThermoFisher (.raw), Spectroswiss signal booster data-acquisition station (.hdf5): "Bruker Solarix (CompassXtract), Bruker Solarix transients, ser and fid (FT magnitude mode only), ThermoFisher (.raw)"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 326,834. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.