Mass spectrometry calibration

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/mass-spectrometry-calibration

Use when after peak detection when you have a detected peaks table with m/z values and need to correct systematic mass drift or inaccuracy before peak alignment across multiple batches.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill mass-spectrometry-calibration

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.0 KB, ~1.1k tokens by cl100k_base, as published. Nobody here has run it

mass-spectrometry-calibration

License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->

Summary

Recursive mass correction refines m/z accuracy of detected peaks in untargeted LC/HRMS data by recalibrating mass coordinates using internal reference standards or lock masses. This skill is essential for multi-batch population-scale studies where consistent mass accuracy across samples directly impacts peak alignment, annotation reliability, and downstream compound identification.

When to use

Apply this skill after peak detection when you have a detected peaks table with m/z values and need to correct systematic mass drift or inaccuracy before peak alignment across multiple batches. Particularly critical in population-scale untargeted LC/HRMS studies (n > 500) where batch-to-batch variation accumulates and impacts m/z alignment fidelity.

When NOT to use

  • Input peaks table has already been externally calibrated or is from targeted analysis with predetermined m/z windows.
  • Internal reference standards or lock masses are unavailable or unreliable across the batch.
  • Single-sample analysis where batch-to-batch correction is not applicable.

Inputs

  • Detected peaks table (with m/z values, retention time, and peak properties from peak detection step)
  • Internal reference standard list or lock mass calibrant identities
  • Mass spectrometry raw data (mzXML, mzML, or netCDF format)

Outputs

  • Corrected peaks table with recalibrated m/z values
  • Pre- and post-correction m/z accuracy metrics and comparison report
  • Mass calibration curve or correction model used

How to apply

Load the detected peaks table containing m/z values and peak properties from the prior peak detection step. Apply IDSL.IPA's recursive mass correction algorithm, which recalibrates m/z coordinates using internal reference standards or lock masses to correct for instrumental drift and systematic bias. The algorithm iteratively refines mass accuracy by leveraging known-mass reference compounds or endogenous markers stable across the batch. Generate a corrected peak table with updated m/z coordinates. Validate correction by comparing pre- and post-correction m/z accuracy metrics (e.g., ppm error distributions) and confirm that m/z shifts are within acceptable tolerance before exporting the final corrected peak dataset for downstream alignment and annotation.

Related tools

Examples

library(IDSL.IPA); IPA_workflow("path/to/IPA_parameters.xlsx")

Evaluation signals

  • M/z error (ppm) distribution narrows and shifts toward zero after correction compared to pre-correction state.
  • Internal reference standards recover expected m/z values within instrumental tolerance (typically ≤5 ppm for HRMS).
  • Corrected peaks successfully align across multiple batches with reduced m/z mismatch artifacts.
  • No systematic m/z drift remains as a function of retention time or scan order.
  • Peak counts and properties (area, width, S/N) remain unchanged post-correction, confirming that mass calibration does not introduce false peak loss or duplication.

Limitations

  • Requires availability and stability of internal reference standards or lock masses across all samples in the batch; poor calibrant recovery degrades correction quality.
  • Recursive algorithm convergence depends on parameter tuning (number of iterations, reference mass weighting); suboptimal settings may under- or over-correct.
  • Correction accuracy is limited by instrument mass resolution and stability; very long analytical runs or instrument drift exceeding reference standard capacity may necessitate sub-batch recalibration.
  • No changelog available in the repository, so version-specific algorithm changes are not explicitly documented.

Evidence

  • [other] IDSL.IPA includes a recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy of detected peaks.: "IDSL.IPA includes a recursive mass correction algorithm as part of its suite of peak processing algorithms, applied after peak detection to refine mass accuracy of detected peaks."
  • [other] Load detected peaks table containing m/z values and peak properties from prior detection step. Apply recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using internal reference standards or lock masses.: "Apply recursive mass correction algorithm as implemented in IDSL.IPA to recalibrate m/z values using internal reference standards or lock masses."
  • [readme] recursive mass correction, retention time correction across multiple batches and peak annotation are part of the workflow: "IDSL.IPA is a suite of new algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation, recursive mass correction, retention time correction"
  • [other] Compare pre- and post-correction m/z accuracy metrics and export final corrected peak dataset.: "Compare pre- and post-correction m/z accuracy metrics and export final corrected peak dataset."
  • [readme] Population scale untargeted LC/HRMS studies context: "IDSL.IPA generates comprehensive and high-quality datasets from untargeted analysis of organic small molecules for population-size studies."

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.