Ion mobility calibration curve fitting

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/ion-mobility-calibration-curve-fitting

Use when you have TWIM-MS experimental data with arrival times and m/z values, and access to calibrant reference standards with known CCS values (typically loaded from a calibration template).From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill ion-mobility-calibration-curve-fitting

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.2 KB, ~1.2k tokens by cl100k_base, as published. Nobody here has run it

ion-mobility-calibration-curve-fitting

Summary

Fit a regression model (linear or polynomial) to drift time vs. collision cross section (CCS) reference standards to establish a calibration curve for converting experimental TWIM-MS arrival times into calibrated CCS values. This is a core step in high-dimensional multi-omic ion mobility mass spectrometry data analysis.

When to use

You have TWIM-MS experimental data with arrival times and m/z values, and access to calibrant reference standards with known CCS values (typically loaded from a calibration template). You need to convert raw arrival times into calibrated CCS values across the m/z range before downstream biomolecular class assignment or quantification.

When NOT to use

  • Arrival times have already been manually converted to drift times using a different method or instrument calibration—re-fitting may introduce inconsistency.
  • Reference calibrant standards are unavailable, unlabeled, or have uncertain CCS values.
  • The experimental m/z range extends far beyond the m/z coverage of reference standards, leading to extrapolation beyond the validated calibration domain.

Inputs

  • TWIM-MS arrival times (time at detector) and m/z values from experimental sample
  • Instrument-specific time-of-flight offset parameter
  • Calibrant reference standards with known CCS values
  • Calibration template (data structure defining reference standards and CCS assignments)

Outputs

  • Calibration curve model (linear or polynomial regression coefficients)
  • Calibrated CCS values for all ions in experimental dataset
  • CCS table with m/z, charge state, drift time, and quality metrics
  • Calibration quality report (e.g., residuals, R² goodness-of-fit)

How to apply

Load calibrant reference standards with known CCS values from the calibration template. Convert experimental arrival times to drift times by subtracting the instrument-specific time-of-flight offset. Fit a linear or polynomial regression model to the calibrant reference standards, mapping drift time to CCS across the m/z range. Apply the resulting calibration function to the experimental drift times to generate calibrated CCS values for all ions. Export the calibrated CCS table with associated m/z, charge state, and quality metrics (e.g., residuals or goodness-of-fit). Validate that calibration residuals are acceptable and that the curve spans the full m/z range of experimental data.

Related tools

  • MOCCal (Python application that implements CCS calibration as a core workflow step, including data import, drift time conversion, calibrant loading, and calibration curve fitting for TWIM-MS data) — https://github.com/HinesLab/MOCCal
  • DEIMoS (Dependency for MOCCal when processing raw (unprocessed) calibration files; version 1.3.2 required for RawDT workflow) — http://github.com/pnnl/deimos

Evaluation signals

  • Calibration curve residuals (difference between fitted and reference CCS values) are within acceptable bounds (typically < 2% relative error for high-quality standards).
  • Goodness-of-fit metric (R² or adjusted R²) is ≥ 0.99, indicating the model explains ≥ 99% of variance in reference standards.
  • Calibrated CCS values for unknown samples fall within the m/z and drift time range spanned by the reference standards (no extrapolation).
  • Quality metrics (charge state, m/z assignment) are correctly propagated to output CCS table and match input experimental data.
  • Calibration is reproducible: re-fitting with the same standards and parameters yields identical or near-identical CCS values (bit-identical or within floating-point tolerance).

Limitations

  • TWIM platforms record arrival time (time at detector) rather than drift time (time in TWIM cell), and the conversion requires an accurate instrument-specific time-of-flight offset; incorrect offset propagates systematic error into all calibrated CCS values.
  • Linear or polynomial regression assumes a smooth, monotonic relationship between drift time and CCS; non-ideal behavior (e.g., instrument hysteresis or space-charge effects) may violate this assumption and degrade calibration accuracy at extreme m/z or CCS values.
  • Reference calibrant standards must cover the m/z and CCS range of experimental data; sparse or unevenly distributed standards lead to poor fit quality or unreliable predictions in sparse regions.
  • No changelog provided; version history and known issues are not documented in the repository README.

Evidence

  • [other] Convert arrival times to drift times by accounting for the time-of-flight offset specific to the instrument platform.: "Convert arrival times to drift times by accounting for the time-of-flight offset specific to the instrument platform."
  • [other] Load calibrant reference standards with known CCS values from the calibration template.: "Load calibrant reference standards with known CCS values from the calibration template."
  • [other] Apply linear or polynomial regression to establish a calibration curve mapping drift time to CCS across the m/z range.: "Apply linear or polynomial regression to establish a calibration curve mapping drift time to CCS across the m/z range."
  • [other] Apply the calibration function to experimental arrival times to generate calibrated CCS values for all ions.: "Apply the calibration function to experimental arrival times to generate calibrated CCS values for all ions."
  • [readme] TWIM platforms record the time at which the ion reaches the detector (arrival time) rather than the time an ion spends within the TWIM cell (drift time).: "TWIM platforms record the time at which the ion reaches the detector (arrival time) rather than the time an ion spends within the TWIM cell (drift time)."
  • [readme] Functionality includes collision cross section (CCS) calibration, experimental data biomolecular class assignment, and experimental class-specific CCS calculations.: "Functionality includes collision cross section (CCS) calibration, experimental data biomolecular class assignment, and experimental class-specific CCS calculations."

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.