Spectral denoising formula method

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/spectral-denoising-formula-method

Use when you have a noisy MS/MS spectrum and need to identify and remove chemical noise ions (as opposed to electronic noise). You have the precursor compound's SMILES string or molecular formula and its adduct type.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill spectral-denoising-formula-method

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

8.6 KB, ~1.5k tokens by cl100k_base, as published. Nobody here has run it

spectral-denoising-formula-method

Summary

Formula-based denoising removes chemical noise ions from MS/MS spectra by evaluating whether each fragment ion could be formed from a chemically plausible subformula loss derived from the precursor compound's molecular formula and adduct state. This method improves high-confidence compound identification by retaining only ions consistent with the compound's structure.

When to use

Apply this skill when you have a noisy MS/MS spectrum and need to identify and remove chemical noise ions (as opposed to electronic noise). You have the precursor compound's SMILES string or molecular formula and its adduct type. Your goal is to distinguish true fragment ions from chemical artifacts by checking whether each m/z value could plausibly arise from a neutral loss of a subformula derived from the parent ion.

When NOT to use

  • The input spectrum contains only electronic noise (identical peak intensities ≥4 occurrences); use electronic_denoising instead or apply it first.
  • You lack reliable chemical structure information (SMILES or formula); formula_denoising requires accurate precursor formula to generate valid subformula candidates.
  • The adduct type is unknown or ambiguous; incorrect adduct specification will produce incorrect master formula and lead to false noise tagging.

Inputs

  • noisy MS/MS spectrum as numpy array (m/z, intensity columns)
  • compound SMILES string or molecular formula
  • adduct type string (e.g., '[M+H]+', '[M+Na]+')

Outputs

  • denoised MS/MS spectrum (numpy array with m/z, intensity columns)
  • denoise tags for each ion ('valid' or 'noise')
  • entropy similarity score comparing denoised spectrum to reference spectrum

How to apply

Extract the master molecular formula from the input SMILES string and adduct type using prep_formula, which adjusts the formula based on adduct ionization state. Compute precursor ion m/z statistics using get_pmz_statistics. Populate all chemically possible subformulas (representing all possible neutral losses) from the master formula using get_all_subformulas. For each fragment ion in the spectrum, call check_candidates to test whether a plausible subformula loss could produce that m/z value. Tag each ion as valid or noise using get_denoise_tag based on whether a candidate subformula loss was found. Retain only ions tagged as valid. This approach eliminates chemical noise while preserving genuine fragment ions consistent with the compound's structure.

Related tools

Examples

peak_denoised = sd.spectral_denoising(peak_with_noise, 'O=c1nc[nH]c2nc[nH]c12', '[M+Na]+')

Evaluation signals

  • Entropy similarity score between denoised spectrum and ground-truth/reference spectrum should be higher than entropy similarity of raw noisy spectrum versus reference (indicating noise removal improved spectral quality).
  • All retained ions (tagged 'valid') must correspond to m/z values explainable by neutral losses of subformulas from the master formula; no retained ion should lack a plausible subformula candidate.
  • The number of ions removed should be consistent with the proportion of chemical noise in the original spectrum; compare ion count before and after denoising against known noise patterns from NIST23 database benchmarks.
  • Spectrum entropy should not increase after denoising; normalized entropy of denoised spectrum should be ≤ normalized entropy of noisy spectrum, reflecting reduced randomness from noise removal.
  • The precursor ion region should be preserved in the denoised spectrum; the precursor m/z should remain after denoising since it is always valid.

Limitations

  • Formula_denoising accuracy depends critically on correct SMILES input and accurate adduct specification; incorrect structural or ionization information will generate wrong subformula candidates and cause false noise tagging or false negatives.
  • The method cannot distinguish between true fragment ions and chemical noise ions that happen to match subformula loss m/z values by coincidence, particularly for low-mass fragments common across many compounds.
  • Performance has been empirically tested on NIST23 database; behavior on spectra from other instruments, ionization methods, or collision energies may differ.
  • Computational cost scales with the complexity of the molecular formula; highly complex polymers or large biomolecules may generate prohibitively large subformula lists.

Evidence

  • [other] The formula_denoising function removes chemical noise ions in MS/MS spectra by evaluating if it could be formed from a chemically plausible subformula loss: "The formula_denoising function removes chemical noise ions in MS/MS spectra by evaluating if it could be formed from a chemically plausible subformula loss"
  • [other] Apply formula_denoising by: (a) extracting the master formula from SMILES and adduct using prep_formula, (b) computing precursor ion statistics with get_pmz_statistics, (c) populating all possible subformulas from the master formula using get_all_subformulas, (d) checking each fragment ion against candidate subformula losses using check_candidates, and (e) tagging ions as valid or noise using get_denoise_tag.: "Apply formula_denoising by: (a) extracting the master formula from SMILES and adduct using prep_formula, (b) computing precursor ion statistics with get_pmz_statistics, (c) populating all possible"
  • [intro] Noise ions in MS/MS spectra are largely categorized as 1. electronic noises and 2. chemical noises.: "Noise ions in MS/MS spectra are largely categorized as 1. electronic noises and 2. chemical noises."
  • [other] For any given fragment ion, the algorithm will try to find a plausible subformula loss that could form this ion (function check_cnadidates): "For any given fragment ion, the algorithm will try to find a plausible subformula loss that could form this ion"
  • [readme] peak_denoised = sd.spectral_denoising(peak_with_noise, smiles, adduct): "peak_denoised = sd.spectral_denoising(peak_with_noise, smiles, adduct)"
  • [other] According to empiracally tested on NIST23 database, in a given spectrum, the number of ions with identical intensities more than 4 is extremely unlikely: "According to empiracally tested on NIST23 database, in a given spectrum, the number of ions with identical intensities more than 4 is extremely unlikely"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.