Signal smoothing preprocessing

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/signal-smoothing-preprocessing

Use when when working with raw LC-HRMS profile-mode data containing noisy chromatographic signals, apply this skill before peak detection. Smoothing is particularly needed when the signal-to-noise ratio is low or when gradient-based peak detection would be compromised by high-frequency noise.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill signal-smoothing-preprocessing

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

5.8 KB, 856 tokens by cl100k_base, as published. Nobody here has run it

signal-smoothing-preprocessing

License: noncommercial — confirm your use is a permitted (noncommercial) purpose before applying; commercial use requires a separate license (see metadata.tool_license). <!-- asb-license-banner -->

Summary

Apply smoothing to LC-HRMS profile-mode chromatographic signals to reduce noise and enable robust local-maxima detection. This preprocessing step is essential before gradient-descent peak-picking to ensure reliable identification of chromatographic peaks versus background artifacts.

When to use

When working with raw LC-HRMS profile-mode data containing noisy chromatographic signals, apply this skill before peak detection. Smoothing is particularly needed when the signal-to-noise ratio is low or when gradient-based peak detection would be compromised by high-frequency noise. Use this as the first step in the PeakBot workflow to prepare data for subsequent local-maxima identification.

When NOT to use

  • Input data is already centroided or in profile-mode but has been pre-processed by another peak-picking tool
  • Signal-to-noise ratio is already very high (smoothing may unnecessarily degrade peak resolution)
  • The downstream workflow requires preservation of high-frequency spectral features (e.g., isotope-pattern fidelity for MS/MS annotation)

Inputs

  • LC-HRMS profile-mode data (raw chromatographic signal as function of retention time and m/z)
  • Raw chromatographic signal array (1D or 2D: retention time × m/z)

Outputs

  • Smoothed chromatographic signal array (retention time × m/z with reduced noise)
  • Preprocessed signal ready for gradient computation and local-maxima detection

How to apply

Load the LC-HRMS profile-mode data (e.g., from mzML or vendor formats) and apply a smoothing algorithm to the chromatographic signal dimension (retention time axis). The smoothing reduces high-frequency noise while preserving peak shape and retention-time accuracy, enabling the subsequent gradient-descent algorithm to reliably compute gradients and identify local maxima. The smoothed signal is then used as input to the gradient computation step. No specific smoothing parameters are detailed in the source material, but the smoothing must preserve peak morphology sufficiently that estimated peak borders and centers remain accurate for the downstream matching against reference features.

Related tools

Evaluation signals

  • Smoothed signal retains peak shape and does not shift retention-time positions of true peaks by more than the instrument's RT precision tolerance
  • Gradient computation on smoothed signal yields stable, interpretable gradients without spurious zero-crossings in noise-only regions
  • Downstream local-maxima detected on smoothed signal match reference peaks from the user-defined reference list with expected retention-time agreement
  • Visual inspection: smoothed chromatogram shows clear peak definition with suppressed noise spikes; compare smoothed vs. raw signal to verify noise reduction without over-smoothing

Limitations

  • Over-smoothing may merge closely-eluting isomeric peaks or reduce peak height estimates, leading to false negatives in peak detection
  • Smoothing parameters are not explicitly specified in the source material; optimal smoothing strength may require empirical tuning per LC-HRMS platform and gradient method
  • Smoothing is a lossy operation; retention of sufficient spectral detail (e.g., isotope patterns) may be compromised if smoothing is applied across m/z dimension as well as RT

Evidence

  • [other] Load LC-HRMS profile-mode data from the input file. 2. Apply smoothing to the chromatographic signal.: "Load LC-HRMS profile-mode data from the input file. 2. Apply smoothing to the chromatographic signal."
  • [intro] searching for chromatographic peaks using a smoothing and gradient-descend algorithm. The peaks' borders and centers are also estimated in this step: "searching for chromatographic peaks using a smoothing and gradient-descend algorithm. The peaks' borders and centers are also estimated in this step"
  • [other] Compute gradients and identify local maxima using gradient-descent algorithm.: "Compute gradients and identify local maxima using gradient-descent algorithm."

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.