Metabolomic peak quality assessment

Skill HolobiomicsLab/asb-skill-collections/collections/metabolomics/v2/skills/metabolomic-peak-quality-assessment

Use when after peak detection in untargeted LC/HRMS workflows, when you have a list of candidate peaks with signal intensity profiles and need to filter them according to data quality thresholds (signal-to-noise ratio, peak width, baseline separation, and isotopic pairing consistency) before.From its SKILL.md

Install
npx -y skills add HolobiomicsLab/asb-skill-collections --skill metabolomic-peak-quality-assessment

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

One thing to look at

  • 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

What its file declares

Copied from the file, not written here

The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.

SKILL.md

7.8 KB, ~1.3k tokens by cl100k_base, as published. Nobody here has run it

metabolomic-peak-quality-assessment

License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->

Summary

Evaluate detected peaks from LC/HRMS data using quantitative chromatographic properties and signal quality metrics to filter peaks meeting sensitivity, specificity, and reproducibility standards. This skill ensures high-confidence peak lists suitable for population-scale untargeted metabolomics studies.

When to use

After peak detection in untargeted LC/HRMS workflows, when you have a list of candidate peaks with signal intensity profiles and need to filter them according to data quality thresholds (signal-to-noise ratio, peak width, baseline separation, and isotopic pairing consistency) before downstream alignment and annotation.

When NOT to use

  • Input peaks already pass through a different peak quality filter (e.g., from MZmine 2 or xcms vendor workflow) — applying IDSL.IPA's evaluation may introduce redundant or conflicting quality criteria.
  • Data are targeted analysis with pre-defined m/z-RT pairs — use IDSL.IPA's IPA_targeted function instead of the full EIC-to-peak-detection-to-evaluation pipeline.
  • Chromatographic method or instrument differs substantially from supported formats (mzXML, mzML, netCDF) or produces atypical peak shapes for which published metric thresholds do not apply.

Inputs

  • Detected peak list (retention time, m/z, apex intensity, detection confidence scores)
  • EIC signal intensity profiles (continuity and intensity transitions per candidate)
  • Mass spectrometry acquisition parameters (scan rate, baseline noise estimate)

Outputs

  • Filtered peak list with retention time, m/z, peak area, and 19 computed chromatographic properties
  • Quality assessment report with per-peak metrics (S/N, peak width, asymmetry, gaussianity, nIsoPair)
  • Gap-filled peak height tables and pairwise correlation lists for adduct/fragment detection

How to apply

Apply IDSL.IPA's peak property evaluation algorithm to compute 19 chromatographic metrics per detected peak, including signal-to-noise ratio (using baseline, xcms, or RMS methods), peak width, asymmetry factor, USP tailing factor, gaussianity, and nIsoPair/RCS for isotopic coherence. Define cutoff thresholds for each metric based on your chromatographic method and mass spectrometry platform (e.g., S/N > baseline threshold, peak width within expected range, tailing factor near 1.0 for symmetric peaks). Filter retained peaks by applying these thresholds sequentially; peaks failing any criterion are excluded. Rationale: multi-dimensional quality filtering reduces false positives and improves alignment reliability across population-size studies by selecting only peaks with good peak shape, sufficient signal above noise, and consistent isotopic signatures.

Related tools

  • IDSL.IPA (Implements peak property evaluation, calculates 19 chromatographic metrics, applies quality filtering thresholds, and outputs filtered peak lists with confidence scores) — https://github.com/idslme/IDSL.IPA
  • R (Execution environment for IDSL.IPA package and statistical analysis of peak quality metrics)
  • IDSL.UFA (Downstream molecular formula annotation tool integrated with IDSL.IPA filtered peak lists) — https://github.com/idslme/IDSL.UFA
  • IDSL.CSA (Composite spectra generation by clustering recurring ions from quality-filtered peaks) — https://github.com/idslme/IDSL.CSA

Examples

library(IDSL.IPA)
IPA_workflow("path/to/IPA_parameters.xlsx")

Evaluation signals

  • Filtered peak list row count < input candidate count; verify that exclusion rate is consistent with thresholds applied (e.g., typical metabolomics studies report 50–80% retention after quality filtering).
  • All retained peaks have S/N ≥ specified baseline threshold and peak width within biologically plausible range (e.g., 0.01–2 min for typical LC methods).
  • Asymmetry factor and USP tailing factor values cluster near 1.0 for retained peaks; heavily tailed or fronted peaks are excluded or flagged.
  • nIsoPair and RCS metrics confirm isotopic coherence (e.g., ¹³C isotologues detected with expected mass offset and intensity ratio ≈ 1.1× per carbon).
  • Peaks retained after filtering show improved alignment consistency and reduced false positives in downstream cross-sample peak alignment compared to unfiltered candidate list.

Limitations

  • Peak quality metric thresholds are tunable but require instrument-specific calibration; default parameters in IPA_parameters.xlsx may not generalize to all LC/HRMS platforms or chromatographic methods.
  • Highly overlapping or co-eluting peaks may be incorrectly flagged as poor quality even if biologically relevant; visual inspection or targeted EIC review recommended for borderline cases.
  • S/N calculation methods (baseline, xcms, RMS) yield different results; consistent method choice must be specified in PARAM configuration and documented.
  • The 19-metric evaluation assumes standard metabolite mass range and peak shape; atypical compounds (very lipophilic, highly charged, or fragile metabolites) may not meet published thresholds.
  • No built-in changelog documented; version-to-version threshold or metric changes may not be transparent.

Evidence

  • [readme] Peak property evaluation algorithm with 19 metrics: "Calculating 19 chromatographic peak properties such as peak area, nIsoPair, RCS, cumulated intensity, R13C, peak width, RPW, number of separation trays, asymmetry factor, USP tailing factor, skewness"
  • [intro] Position and function in workflow: "algorithms covering extracted ion chromatogram (EIC) candidate generation, peak detection, peak property evaluation"
  • [other] Quality filtering based on signal-to-noise and peak width: "Filter detected peaks according to algorithm-defined quality criteria (signal-to-noise ratio, peak width constraints, baseline separation)."
  • [other] Output includes confidence scores: "Output detected peak list with retention time, m/z, peak apex intensity, and detection confidence scores."
  • [readme] Population-scale application and performance: "IDSL.IPA generates comprehensive and high-quality datasets from untargeted analysis of organic small molecules for population-size studies."
  • [readme] S/N definition variants: "Definition of Signal to Noise ratio (S/N)"

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.