Software mode routing dispatch
Use when you are preparing to run LipidMatch or FluoroMatch and need to select the correct analysis mode for your sample type: lipid profiling, Tween-positive surfactant analysis, or PFAS (per- and polyfluoroalkyl substances) analysis.From its SKILL.md
npx -y skills add HolobiomicsLab/asb-skill-collections --skill software-mode-routing-dispatchAssembled from the repository path, not quoted from the project. Check it against their README if it does not work.
One thing to look at
- 15 stars15 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.
What its file declares
Copied from the file, not written here
The file declares its own license as CC-BY-4.0. That is the author’s claim about this one file, and it is not the same thing as the license GitHub reports for the repository, which is listed with the other numbers below.
SKILL.md
6.8 KB, ~1.1k tokens by cl100k_base, as published. Nobody here has run it
software-mode-routing-dispatch
License: restricted — no clear open-source license detected for the underlying tool; verify licensing before commercial use or redistribution. <!-- asb-license-banner -->
Summary
Configure boolean parameters in LipidMatch to route analysis execution toward lipid detection, Tween-positive detection, or PFAS analysis based on intended application. This skill encodes conditional dispatch logic that determines which algorithmic pathway executes at runtime.
When to use
You are preparing to run LipidMatch or FluoroMatch and need to select the correct analysis mode for your sample type: lipid profiling, Tween-positive surfactant analysis, or PFAS (per- and polyfluoroalkyl substances) analysis. The choice depends on your sample composition and experimental objective, not on input file format or preprocessing state.
When NOT to use
- Input data has already been preprocessed or aligned to a mode-specific database; parameter dispatch occurs at initialization and cannot be changed mid-analysis.
- You have uncertainty about sample type but want to run exploratory analysis across all modes; this skill commits to a single mode and must be repeated separately for each mode comparison.
- The LipidMatch version does not support boolean parameter toggling (e.g., legacy versions prior to LipidMatch-4.2).
Inputs
- LipidMatch configuration template or parameter block
- User specification of analysis application type (PFAS, Lipid, or Tween-positive)
- Input metadata indicating sample composition
Outputs
- Configured parameter block with Lipid and TWeen_pos boolean values set
- Output configuration file ready for LipidMatch or FluoroMatch execution
- Analysis mode dispatch pathway correctly encoded
How to apply
Identify your intended analysis application (PFAS, Lipid, or Tween-positive) from your experimental design or sample metadata. Set the boolean parameters Lipid and TWeen_pos in the LipidMatch configuration block according to a three-state dispatch rule: set Lipid ← TRUE and TWeen_pos ← FALSE for lipid analysis; set Lipid ← FALSE and TWeen_pos ← TRUE for Tween-positive analysis; set both Lipid ← FALSE and TWeen_pos ← FALSE to default to PFAS analysis. Write these parameter assignments into the configuration file before invoking the LipidMatch or FluoroMatch executable. The order of parameter assignment is not significant; the conditional logic reads both flags simultaneously to determine the execution path.
Related tools
- LipidMatch (Primary analysis software whose execution pathway is routed by parameter configuration; implements order-agnostic conditional dispatch logic based on Lipid and TWeen_pos boolean flags) — https://github.com/InnovativeOmics/Core-Match
- FluoroMatch (Sister software supporting identical analysis-mode parameter dispatch via same Lipid and TWeen_pos boolean configuration) — https://github.com/InnovativeOmics/Core-Match
- R (Execution environment in which parameter configuration block is evaluated and conditional dispatch logic is resolved)
Examples
# In R configuration file for LipidMatch:
Lipid <- FALSE
TWeen_pos <- FALSE
# This routes analysis to PFAS detection mode
Evaluation signals
- Configuration file is parseable and contains both Lipid and TWeen_pos boolean assignments with no syntax errors.
- Lipid and TWeen_pos values follow the three-state rule: exactly one of {(TRUE,FALSE), (FALSE,TRUE), (FALSE,FALSE)} is set; mixed states like (TRUE,TRUE) indicate misconfiguration.
- LipidMatch execution log or output metadata confirms the correct analysis mode was selected (e.g., 'Lipid analysis mode active' or 'PFAS default mode active').
- Output feature tables or match scores are consistent with the intended analysis mode (e.g., lipid class annotations present for Lipid mode, PFAS marker compounds for PFAS mode).
- Parameter block is correctly placed in the location specified by the README: immediately after FLOW configuration and before any analysis-specific parameter overrides.
Limitations
- Both boolean parameters set to TRUE is undefined behavior; the README does not document fallback or error handling for this state.
- Parameter dispatch is static at initialization; switching analysis modes requires restarting LipidMatch with a reconfigured parameter block.
- The THREE-state design (Lipid / Tween-pos / PFAS) permits no mixed-mode analysis within a single execution; comparative or exploratory workflows require serial runs.
- No changelog is available, so version-specific parameter behavior or changes are not documented.
Evidence
- [readme] Parameter configuration mechanism and three-state dispatch logic: "Make sure to toggle the following parameters depending on your application, if both are FALSE it defaults to PFAS analysis:
Lipid <- TRUETWeen_pos <- FALSE" - [other] Conditional dispatch is order-agnostic and depends on simultaneous flag state: "LipidMatch implements order-agnostic conditional dispatch via two boolean parameters: setting Lipid to TRUE routes to lipid analysis; setting TWeen_pos to TRUE routes to Tween-positive analysis;"
- [readme] Parameter block placement and integration workflow: "Place any edited script files (genEIC.r, MS1Spectragen.r, Stats.R) into:
LipidMatch-4.2\Flow\LipidMatch_Distribution\LipidMatch_Libraries\Scripts" - [other] Application determines execution pathway based on parameter configuration: "The application determines which analysis mode executes based on parameter configuration."
What ships with it
Read from the repository
Just SKILL.md. No reference files, no scripts.