agentsclimarketplace

Compensation transformation

Skill FridrichMethod/awesome-skills/skills/compensation-transformation

Corrects fluorophore spillover (conventional compensation) or spectral overlap (spectral unmixing) and applies variance-stabilizing transforms (logicle/biexponential, arcsinh, log) for flow and mass cytometry. Covers spillover-matrix estimation from single-stain controls, AutoSpill, the spillover spreading matrix and why panel design (not compensation) bounds resolution, compensate-then-transform ordering, and arcsinh cofactor choice (5 for CyTOF, ~150 for fluorescence, per-channel via flowVS). Use when correcting spectral overlap, preparing data for gating/clustering, choosing logicle vs arcsinh, deciding a cofactor, or distinguishing compensation from spectral unmixing.From its SKILL.md

Install
npx -y skills add FridrichMethod/awesome-skills --skill compensation-transformation

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

2 things to look at

  • no licenseNo license file was found in the repository. Code published without one is not open source by default, so using it at work is a question for whoever answers licensing questions where you are.
  • 13 stars13 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

SKILL.md

11.0 KB, ~2.7k tokens by cl100k_base, as published. Nobody here has run it

Version Compatibility

Reference examples tested with: flowCore 2.14+, flowStats 4.14+, flowWorkspace 4.14+, CATALYST 1.26+.

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters

Notes that bite: estimateLogicle() lives in flowWorkspace (not flowCore). flowCore::spillover() on a flowFrame returns a LIST of keyword matrices (index [[1]]); flowStats::spillover() on single-stain controls returns the matrix DIRECTLY (not a list) - do not index it with $.

If code throws an error, introspect the installed package and adapt rather than retrying.

Compensation and Transformation

"Compensate and transform my cytometry data" -> Remove spillover (matrix subtraction, conventional) or unmix the full spectrum (least squares, spectral), then apply a transform so populations separate.

  • R (conventional): flowCore::compensate() then flowWorkspace::estimateLogicle() + flowCore::transform()
  • R (CyTOF/mass): CATALYST::prepData(..., transform=TRUE, cofactor=5) (arcsinh)
  • R (spectral): linear UNMIXING, not compensation - see the taxonomy

The Single Most Important Modern Insight -- Compensation Corrects the Mean; It Cannot Remove Spreading Error

Conventional compensation inverts a square spillover matrix (peak-channel subtraction); spectral cytometry solves an OVERDETERMINED least-squares unmix over all detectors, with autofluorescence modeled as an extra "fluorophore." Both correct the population MEAN. Neither removes spreading error - the widening of a negative population in a spillover detector that arises from the Poisson counting statistics of the spilled-in photons (Roederer 2001 Cytometry 45:194; Nguyen 2013 Cytometry A 83:306). Compensation does not INTRODUCE spreading; it makes the pre-existing variance visible by re-centering means. The corollaries are load-bearing: (1) a smeared negative cannot be fixed by tuning the matrix - over-compensating to flatten it is data falsification; (2) spreading is fixed at PANEL DESIGN (the Spillover Spreading Matrix identifies which detector pairs to avoid for co-expressed/dim markers), never downstream; (3) calling spectral unmixing "compensation" is a category error - it is a different, overdetermined model.

Method Taxonomy

MethodWhat it doesWhen to useFails when
Acquisition-recorded $SPILLOVERapplies the cytometer-computed matrixtrustworthy single-stain setup at acquisitioncontrols were wrong/missing
Computed compensation (flowStats::spillover)estimates spillover from single-stain controls (medians)conventional flow, controls availablepoor/dim/contaminated controls
AutoSpill (Roca 2021 Nat Commun 12:2890)robust-regression matrix + iterative refinement; AF as endogenous dyehigh-parameter panels; messy controlsreference implementation/setup unavailable
Spectral unmixing (OLS/WLS/Poisson)least-squares unmix full spectrum vs reference spectra + AFspectral cytometers (Aurora, ID7000)wrong/heterogeneous AF; collinear spectra
Logicle / biexponentialdisplay + analysis transform, handles negativesfluorescence flowwrong w clips the negative population
arcsinhvariance-stabilizing transformCyTOF/mass; computational pipelineswrong cofactor compresses dim markers
log10legacyrarely; strictly positive dataany negative values after compensation

Decision Tree by Scenario

ScenarioRecommendedWhy
Conventional flow, $SPILLOVER presentapply recorded matrix -> estimateLogicletrust acquisition controls; logicle handles negatives
Conventional flow, no matrixcompute via flowStats::spillover from single-stains (or AutoSpill)controls drive the matrix; AutoSpill for >12 colors
Spectral cytometerUNMIX (do NOT compensate), then arcsinh at ~150/per-channel (NOT 5)overdetermined system; spectral data is fluorescence-scale, not ion counts
CyTOF / massarcsinh cofactor 5; spillover via CATALYST compCytof if neededmetals barely spill (~1-4%), but oxide/impurity is real
Dim marker driving a borderline calltest per-channel cofactor (flowVS)a fixed cofactor can manufacture/erase the population

Compensate-Then-Transform Ordering (load-bearing)

Compensation/unmixing is LINEAR and must run on untransformed data; applying it after a nonlinear transform is mathematically invalid. estimateLogicle() must run on ALREADY-COMPENSATED data so the w/a parameters reflect the post-compensation negative spread. Negative values after compensation are expected and meaningful - do NOT clip to zero before transforming (handling negatives is the entire reason logicle/arcsinh exist; log cannot).

Apply or Compute Compensation

Goal: Apply the recorded matrix, or estimate one from single-stain controls.

Approach: compensate() takes a compensation object built from the matrix; flowStats::spillover() estimates from single-stain controls and returns the matrix directly.

library(flowCore)

comp <- compensation(spillover(fcs)[[1]])      # flowCore: flowFrame -> list of keyword matrices
fcs_comp <- compensate(fcs, comp)

library(flowStats)
ctrls <- read.flowSet(list.files('controls', pattern = '\\.fcs$', full.names = TRUE))
comp_matrix <- spillover(ctrls, unstained = 'Unstained.fcs', fsc = 'FSC-A', ssc = 'SSC-A',
                         patt = '-A$', method = 'median')   # flowStats: returns the matrix directly

Logicle / Biexponential Transform (fluorescence)

Goal: Display and analyze compensated fluorescence with negatives handled honestly.

Approach: estimateLogicle() (flowWorkspace) derives w from the data's most-negative events; apply with transform().

library(flowWorkspace)

fluo <- colnames(fcs_comp)[grepl('-A$', colnames(fcs_comp)) & !grepl('FSC|SSC', colnames(fcs_comp))]
lgcl <- estimateLogicle(fcs_comp, channels = fluo)   # data-driven w; t=262144, m=4.5, a=0 defaults
fcs_t <- transform(fcs_comp, lgcl)

Arcsinh Transform (CyTOF cofactor 5; fluorescence/spectral ~150 or per-channel)

Goal: Variance-stabilize mass-cytometry counts (or any pipeline feeding clustering).

Approach: asinh(x/cofactor); flowCore's arcsinhTransform is asinh(a + b*x) + c, so set b=1/cofactor. CATALYST prepData defaults cofactor=5.

COFACTOR <- 5      # standard CyTOF cofactor, codified in the CATALYST workflow (Nowicka 2017); ~150 for fluorescence

asinhT <- arcsinhTransform(transformationId = 'asinh', a = 0, b = 1/COFACTOR, c = 0)
fcs_t  <- transform(fcs, transformList(marker_channels, asinhT))

# CATALYST path (CyTOF): cofactor=5 default; OVERRIDE for fluorescence/spectral
sce <- CATALYST::prepData(fs, panel, md, transform = TRUE, cofactor = COFACTOR)

Per-Method Failure Modes

Over-compensation (negative pull-down)

Trigger: matrix slope over-estimated from dim controls. Mechanism: subtraction overshoots. Symptom: negative population pulled below zero, "comma" shape. Fix: controls at least as bright as the sample; AutoSpill regression; never hand-tune to flatten spread.

Wrong logicle width clips negatives

Trigger: fixed w instead of estimateLogicle. Mechanism: linear region too narrow. Symptom: negative population piled on the axis. Fix: estimate w on compensated data.

Cofactor compresses a dim marker

Trigger: cofactor 5 on fluorescence (or 150 on CyTOF). Mechanism: linear region mismatched to the noise band. Symptom: dim-positive collapses into the negative; clusters don't reproduce. Fix: 5 for CyTOF, ~150 for fluorescence; per-channel via flowVS::estParamFlowVS.

Compensating spectral data

Trigger: treating Aurora data as conventional. Mechanism: subtraction is the wrong model for an overdetermined system. Symptom: residual spread, false positives. Fix: unmix against single-stain reference spectra + unstained AF.

Quantitative Thresholds

ThresholdSourceRationale
arcsinh cofactor = 5 (mass)Nowicka 2017 F1000Res 6:748 (CATALYST workflow)matches CyTOF ion-count near-zero noise band
arcsinh cofactor ~150 (fluorescence)community/CATALYST convention (not a derived optimum)PMT photon scale is far larger; per-channel flowVS supersedes
comp control >= sample brightnessRoederer 2001 Cytometry 45:194slope estimated over the widest lever arm; extrapolation amplifies error
spreading is intensity-dependent (~sqrt of signal)Nguyen 2013 Cytometry A 83:306SSM is normalized to be gain-independent for panel design

Common Errors

Error / symptomCauseSolution
compensate() channel mismatchmatrix colnames != FCS channelsalign names before compensate
all-negative after transformtransform applied before/without compensationcompensate on linear data first
estimateLogicle not foundcalled from flowCoreit lives in flowWorkspace
arcsinhTransform ignores "cofactor"param is b, not cofactorset b = 1/cofactor

References

  • Roederer 2001 Cytometry 45(3):194-205 — spreading error / compensation artifacts.
  • Nguyen 2013 Cytometry A 83(3):306-315 — spillover spreading matrix; panel design.
  • Roca 2021 Nat Commun 12:2890 — AutoSpill robust-regression compensation.
  • Parks 2006 Cytometry A 69(6):541-551 — logicle display.
  • Moore & Parks 2012 Cytometry A 81(4):273-277 — logicle operational update.
  • Bendall 2011 Science 332(6030):687-696 — CyTOF mass cytometry; arcsinh-median analysis.
  • Nowicka 2017 F1000Research 6:748 — CATALYST workflow; codifies the cofactor-5 convention.
  • Azad 2016 BMC Bioinformatics 17:291 — flowVS per-channel cofactor.
  • Chevrier 2018 Cell Syst 6(5):612-620 — CyTOF spillover compensation (CATALYST).

Related Skills

  • fcs-handling - Load FCS and retrieve the spillover keyword first
  • gating-analysis - Gate on the transformed, compensated scale
  • clustering-phenotyping - Cluster compensated, transformed data
  • cytometry-qc - QC before and after preprocessing
  • imaging-mass-cytometry/data-preprocessing - Shared arcsinh/metal-channel conventions
  • spatial-transcriptomics/spatial-proteomics - Spectral/metal unmixing context

What ships with it: 2 files

5.6 KB alongside SKILL.md

examples/

Keep looking

Skills are one crate of 325,949. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.