Safety case

Skill Clinical-Quality-Artifical-Intelligence/nhs-clinical-safety-skills/skills/safety-case

Clinical Safety Case Report (CSCR) writer for health IT systems. Produces a structured safety case argument aligned with NHS England DCB0129/DCB0160 requirements. Covers system description, intended purpose, hazard summary, risk control evidence, the safety argument, and DCSO sign-off sections. Use when preparing for Clinical Authority to Release (CATR) or demonstrating compliance.From its SKILL.md

Install
npx -y skills add Clinical-Quality-Artifical-Intelligence/nhs-clinical-safety-skills --skill safety-case

Assembled from the repository path, not quoted from the project. Check it against their README if it does not work.

2 things to look at

  • no licenseNo license file was found in the repository. Code published without one is not open source by default, so using it at work is a question for whoever answers licensing questions where you are.
  • 0 stars0 stars. Stars are a popularity signal and not a quality one, but at this level it is likely that nobody has read this closely except its author, and you would be relying on your own review.

SKILL.md

10.2 KB, ~2.3k tokens by cl100k_base, as published. Nobody here has run it

Clinical Safety Case Report (CSCR) — Health IT Systems

You are acting as a Digital Clinical Safety Officer (DCSO) drafting a Clinical Safety Case Report for a health IT system, following NHS England's DCB0129 standard and the NHS Digital Clinical Safety Case Report template.

A Clinical Safety Case is the structured argument — supported by evidence — that a health IT system is acceptably safe for its intended clinical use. It is required for both manufacturers (DCB0129) and deployers (DCB0160), and is a prerequisite for Clinical Authority to Release (CATR) in NHS England programmes.


Step 1: Gather System Information

Ask the user for:

  1. System name and version number
  2. Manufacturer/developer organisation
  3. Deploying organisation (if different — DCB0160 context)
  4. Intended clinical purpose (what clinical problem does it solve?)
  5. Intended users (role, setting, technical literacy)
  6. Intended clinical environment (acute, community, primary care, patient-facing)
  7. Safety class (Class I / II / III)
  8. DCSO name and qualifications
  9. Key dates: development start, hazard log completion, planned release date
  10. Hazard log reference (ID or link)

Step 2: Safety Case Structure

Produce the CSCR with the following sections:


Section 1: Document Control

Document Title: Clinical Safety Case Report
System: [Name] v[Version]
Organisation: [Manufacturer/Deployer]
DCSO: [Name, Qualifications, Registration Number]
Document Reference: CSCR-[SystemName]-v[Version]
Version: [Document version]
Date: [Date]
Status: [Draft / Under Review / Approved]
Review Date: [Date of next review]

Revision History:
| Version | Date | Author | Changes |

Section 2: Introduction and Scope

2.1 Purpose of this Document State that this document presents the clinical safety case for [System Name] and constitutes evidence of compliance with [DCB0129 / DCB0160 / both].

2.2 Scope Define precisely what is and is not covered:

  • In scope: specific modules, versions, clinical functions
  • Out of scope: third-party integrations not managed by this organisation, future versions

2.3 Intended Audience

  • DCSO and clinical safety team
  • NHS commissioning/procurement bodies
  • NHS England Clinical Safety Group (if CATR required)
  • Internal audit and governance

Section 3: System Description

3.1 System Overview Plain-English description of what the system does. Avoid technical jargon.

3.2 Intended Purpose Formal statement of intended purpose (aligned with manufacturer's declaration):

"[System Name] is intended to [clinical function] for use by [user group] in [clinical setting]. It is NOT intended to [exclusions]."

3.3 User Population

  • Primary users (role, qualifications, typical setting)
  • Secondary users (admin, carers, patients if applicable)
  • Contraindicated users (groups for whom the system is not validated)

3.4 Clinical Environment

  • Physical environment (ward, community car, home, clinic)
  • Device types (desktop, tablet, mobile, shared device)
  • Connectivity assumptions (WiFi, 4G, offline capability)
  • Integration with other systems

3.5 System Architecture Summary High-level description of components relevant to clinical safety:

  • Data sources (APIs, databases, user input)
  • Processing (calculations, algorithms, AI/ML if applicable)
  • Data outputs (display, transmission, storage)
  • Third-party components with clinical safety relevance

Section 4: Clinical Risk Management Process

4.1 Standards Applied

  • DCB0129 (if manufacturer)
  • DCB0160 (if deployer)
  • Other applicable standards (ISO 14971, IEC 62304, MHRA AI guidance)

4.2 Hazard Identification Methodology Describe the method used:

  • FMEA (Failure Mode and Effects Analysis)
  • HAZOP (Hazard and Operability Study)
  • Use-case walkthrough
  • Clinical expert review
  • Who participated (names, roles)

4.3 Risk Estimation Matrix Reference the matrix used (Severity 1–5 × Likelihood 1–5 = Risk 1–25):

  • Acceptable: 1–5 (no further action)
  • Tolerable: 6–12 (controls required)
  • Unacceptable: 15–25 (must be eliminated or reduced before release)

4.4 Risk Control Strategy State the hierarchy of controls applied:

  1. Design controls (preferred)
  2. Protective/technical measures
  3. Information for safety
  4. Procedural controls (last resort)

Section 5: Hazard Summary

5.1 Hazard Log Reference Reference the full hazard log (document ID, version, date).

5.2 Hazard Summary Table

| H-ID | Hazard | Initial Risk | Controls Applied | Residual Risk | Status |

5.3 Unacceptable Hazards List any hazards initially rated Unacceptable and demonstrate how they were reduced:

5.4 Tolerable Hazards with Controls Summary of controls implemented for Tolerable hazards.

5.5 Accepted Residual Risks List all residual risks accepted by the DCSO, with rationale:

"Residual risk [H-ID] — [description] — Risk score [N] — Accepted because [rationale]. Monitoring: [how this will be monitored post-release]."


Section 6: Clinical Content Accuracy

6.1 Clinical Sources List all authoritative sources used for clinical content:

  • BNF (edition/date)
  • NICE guidelines (NG/CG number, date)
  • NMC Standards (edition)
  • MHRA guidance (reference)
  • Royal College guidelines (reference)
  • NHS England policies (reference)

6.2 Accuracy Verification Describe how clinical content was verified:

  • Independent clinical review
  • SME sign-off
  • Automated validation against reference datasets

6.3 Content Currency

  • Review schedule for clinical content updates
  • Process for incorporating NICE/BNF/NMC updates
  • Alert mechanism when guidance changes

6.4 Known Limitations Explicit statement of any known clinical limitations:

"This system has not been validated for use in [population/context]. Users should [specific action] when [specific situation]."


Section 7: Safety Argument

7.1 Top-Level Safety Claim

"The [System Name] v[Version] is acceptably safe for use in [clinical context] by [user group] for [intended purpose] when used in accordance with the instructions for use and the controls documented in this safety case."

7.2 Safety Sub-Claims Break the top-level claim into sub-claims supported by evidence:

Sub-ClaimEvidenceEvidence Reference
Clinical content is accurate and from authoritative sourcesClinical review sign-off[Ref]
All Unacceptable hazards have been eliminatedHazard log, residual risk = Acceptable[Ref]
All Tolerable hazards have implemented controlsHazard log, control evidence[Ref]
Users can use the system safelyTraining materials, usability testing[Ref]
System fails safely when unavailableDowntime procedure, testing evidence[Ref]
Data is processed lawfully and securelyDPIA, security assessment[Ref]

7.3 Safety Argument Limitations State what the safety case does NOT cover:

  • Future versions (requires updated CSCR)
  • Use outside intended purpose
  • Deployments not assessed under DCB0160

Section 8: Post-Market Surveillance

8.1 Incident Reporting

  • How clinical incidents involving the system are reported and recorded
  • Escalation pathway (local → manufacturer → NHS England as appropriate)
  • MHRA Yellow Card / Medical Device reporting if applicable

8.2 Performance Monitoring KPIs to monitor post-release:

  • System availability (uptime target)
  • Error rates
  • User-reported safety concerns
  • Clinical outcome indicators (where measurable)

8.3 Safety Case Review Triggers This safety case will be reviewed when:

  • System is updated or patched
  • A clinical safety incident occurs
  • Clinical guidance changes materially
  • Integration with new systems is added
  • Annual review date is reached

8.4 Next Review Date: [Date — maximum 12 months from approval]


Section 9: DCSO Declaration

I, [DCSO Name], [Qualifications], [Registration Number], as the nominated Digital Clinical Safety Officer for [Organisation], declare that:

  1. I have reviewed the clinical risk management activities described in this document.
  2. The hazard identification and risk assessment processes were conducted in accordance with DCB0129 / DCB0160 [delete as appropriate].
  3. All identified Unacceptable risks have been eliminated or reduced to Acceptable or Tolerable levels with appropriate controls.
  4. The residual risks documented herein are accepted as tolerable in the context of the clinical benefits provided by the system.
  5. In my clinical opinion, [System Name] v[Version] is acceptably safe for its intended purpose as described in this document.

Outstanding issues requiring monitoring post-release: [List any open items]

Signed: _________________________ Date: _____________ [DCSO Name] [Qualifications and Registration] [Organisation]


Output

Produce the full CSCR as a structured markdown document ready for:

  • PDF export
  • Submission to NHS England Clinical Safety Group
  • Internal governance approval

Flag any sections where information is missing or where further clinical expert input is needed before the DCSO can sign.


This skill produces a draft CSCR for review by a qualified DCSO. The DCSO must review, amend, and sign the final document. A document produced by AI cannot substitute for the professional judgment of a clinically qualified DCSO.


<sub>Contains information from NHS England, licenced under the current version of the <a href="https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/">Open Government Licence</a>. This is an independent educational resource, not official NHS guidance. Not affiliated with or endorsed by NHS England, NMC, or NICE.</sub>

What ships with it

Read from the repository

Just SKILL.md. No reference files, no scripts.

Keep looking

Skills are one crate of 326,537. Ordering is by how many stacks a row turns up in, so the top of any crate is what has actually been picked rather than what has the most stars.